{"id":3812,"date":"2025-06-24T18:35:53","date_gmt":"2025-06-24T16:35:53","guid":{"rendered":""},"modified":"2025-06-24T18:52:12","modified_gmt":"2025-06-24T16:52:12","slug":"ut-reflecteurs-generatrices-trous-generatrices-et-capteurs-monoelement-au-contact","status":"publish","type":"page","link":"https:\/\/www.extende.com\/fr\/la-simulation-cnd\/documentation\/validation-experimentale-des-modeles-civa\/validation-experimentale-des-modeles-civa-en-ultrasons\/ultrasons-reflecteurs-artificiels\/reflecteurs-generatrices\/ut-reflecteurs-generatrices-trous-generatrices-et-capteurs-monoelement-au-contact\/","title":{"rendered":"UT &#8211; R\u00e9flecteurs G\u00e9n\u00e9ratrices  &#8211; Trous g\u00e9n\u00e9ratrices et capteurs mono\u00e9l\u00e9ment au contact"},"content":{"rendered":"<p>Vue globale:<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<div style=\"text-align:center;\">\n<table border=\"1\" cellpadding=\"2\" cellspacing=\"0\" style=\"text-align: center;\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\">Capteur contact<\/td>\n<td style=\"text-align: center;\">2,0\u00a0MHz 20*22\u00a0mm<\/td>\n<td style=\"text-align: center;\">2,0\u00a0MHz \u00d812,7\u00a0mm<\/td>\n<td style=\"text-align: center;\">2,25\u00a0MHz \u00d812,7\u00a0mm<\/td>\n<td style=\"text-align: center;\">2,25\u00a0MHZ \u00d86,35\u00a0mm<\/td>\n<td style=\"text-align: center;\">4,35\u00a0MHz \u00d812,7\u00a0mm<\/td>\n<td style=\"text-align: center;\">4,8\u00a0MHz \u00d86,35\u00a0mm<\/td>\n<td style=\"text-align: center;\">5,0\u00a0MHz \u00d86,35\u00a0mm<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">P45\u00b0<\/td>\n<td style=\"text-align: center;\">\u00a0<\/td>\n<td style=\"text-align: center;\">\u00a0<\/td>\n<td style=\"text-align: center;\">Trait\u00e9<\/td>\n<td style=\"text-align: center;\">\u00a0<\/td>\n<td style=\"text-align: center;\">\u00a0<\/td>\n<td style=\"text-align: center;\">\u00a0<\/td>\n<td style=\"text-align: center;\">Trait\u00e9<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">P60\u00b0<\/td>\n<td style=\"text-align: center;\">\u00a0<\/td>\n<td style=\"text-align: center;\">\u00a0<\/td>\n<td style=\"text-align: center;\">Trait\u00e9<\/td>\n<td style=\"text-align: center;\">\u00a0<\/td>\n<td style=\"text-align: center;\">\u00a0<\/td>\n<td style=\"text-align: center;\">\u00a0<\/td>\n<td style=\"text-align: center;\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">T45\u00b0<\/td>\n<td style=\"text-align: center;\">Trait\u00e9<\/td>\n<td style=\"text-align: center;\">Trait\u00e9<\/td>\n<td style=\"text-align: center;\">\u00a0<\/td>\n<td style=\"text-align: center;\">Trait\u00e9<\/td>\n<td style=\"text-align: center;\">Trait\u00e9<\/td>\n<td style=\"text-align: center;\">Trait\u00e9<\/td>\n<td style=\"text-align: center;\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">T60\u00b0<\/td>\n<td style=\"text-align: center;\">Trait\u00e9<\/td>\n<td style=\"text-align: center;\">\u00a0<\/td>\n<td style=\"text-align: center;\">\u00a0<\/td>\n<td style=\"text-align: center;\">\u00a0<\/td>\n<td style=\"text-align: center;\">\u00a0<\/td>\n<td style=\"text-align: center;\">\u00a0<\/td>\n<td style=\"text-align: center;\">\u00a0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"titre-accordeon\">\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-accordeon\">Configuration<\/h2>\n<\/p>\n<p>Des comparaisons ont \u00e9galement \u00e9t\u00e9 men\u00e9es entre des r\u00e9sultats exp\u00e9rimentaux et simul\u00e9s pour des inspections de la pi\u00e8ce contenant des TG avec des capteurs mono-\u00e9l\u00e9ments au contact. C\u2019est une pi\u00e8ce plane en acier contenant des TG de \u00d82\u00a0mm entre 4 et 60\u00a0mm de profondeur par pas de 4\u00a0mm. Pour rappel, les param\u00e8tres de l\u2019acier sont : densit\u00e9 de 7,9, vitesses des ondes L : 5900\u00a0m\/s et des ondes T : 3230\u00a0m\/s. Les TG \u00e9tant inspect\u00e9s perpendiculairement \u00e0 leur axe, le mod\u00e8le d\u2019interaction <span class=\"g-color2\">SOV<\/span> a \u00e9t\u00e9 utilis\u00e9.<\/p>\n<\/p>\n<p>Voici la maquette utilis\u00e9e pour cette configuration.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG-1.png\" title=\"\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" class=\"mediabox alignnone wp-image-3659\" height=\"163\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG-1.png\" title=\"\" width=\"300\"><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Les capteurs au contact suivants ont \u00e9t\u00e9 utilis\u00e9s en mode Pulse Echo :<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<div style=\"text-align:center;\">\n<table border=\"1\" cellpadding=\"2\" cellspacing=\"0\" style=\"text-align: center;\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\">Fr\u00e9quence<\/td>\n<td style=\"text-align: center;\">Pastille<\/td>\n<td style=\"text-align: center;\">Mode<\/td>\n<td style=\"text-align: center;\">Profondeur d&rsquo;\u00e9talonnage<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" style=\"text-align: center;\">2,0\u00a0MHz<\/td>\n<td style=\"text-align: center;\">20*22\u00a0mm<\/td>\n<td style=\"text-align: center;\">T45\u00b0<\/td>\n<td style=\"text-align: center;\">52\u00a0mm<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">20*22\u00a0mm<\/td>\n<td style=\"text-align: center;\">T60\u00b0<\/td>\n<td style=\"text-align: center;\">32\u00a0mm<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">\u00d812,7\u00a0mm<\/td>\n<td style=\"text-align: center;\">T45\u00b0<\/td>\n<td style=\"text-align: center;\">20\u00a0mm<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" style=\"text-align: center;\">2,25\u00a0MHz<\/td>\n<td style=\"text-align: center;\">\u00d812,7\u00a0mm<\/td>\n<td style=\"text-align: center;\">L45\u00b0<\/td>\n<td style=\"text-align: center;\">8\u00a0mm<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">\u00d812,7\u00a0mm<\/td>\n<td style=\"text-align: center;\">L60\u00b0<\/td>\n<td style=\"text-align: center;\">4\u00a0mm<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">\u00d86,35\u00a0mm<\/td>\n<td style=\"text-align: center;\">T45\u00b0<\/td>\n<td style=\"text-align: center;\">4\u00a0mm<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">4,35\u00a0MHz<\/td>\n<td style=\"text-align: center;\">\u00d812,7\u00a0mm<\/td>\n<td style=\"text-align: center;\">T45\u00b0<\/td>\n<td style=\"text-align: center;\">36\u00a0mm<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">4,8\u00a0MHz<\/td>\n<td style=\"text-align: center;\">\u00d86,35\u00a0mm<\/td>\n<td style=\"text-align: center;\">T45\u00b0<\/td>\n<td style=\"text-align: center;\">8\u00a0mm<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">5,0\u00a0MHz<\/td>\n<td style=\"text-align: center;\">\u00d86,35\u00a0mm<\/td>\n<td style=\"text-align: center;\">L45\u00b0<\/td>\n<td style=\"text-align: center;\">4\u00a0mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-accordeon\">R\u00e9sultats<\/h2>\n<\/p>\n<p>Pour chaque capteur, le r\u00e9sultat de la simulation du champ L et \/ ou T rayonn\u00e9 dans la pi\u00e8ce et dans le plan d\u2019incidence est affich\u00e9. L\u2019\u00e9talonnage est r\u00e9alis\u00e9 sur le TG le plus proche de la profondeur focale mesur\u00e9e sur ce champ simul\u00e9.<\/p>\n<\/p>\n<p>L\u2019amplitude relative maximale est relev\u00e9e pour chacun des \u00e9chos ; les courbes relatives aux \u00e9chos exp\u00e9rimentaux et simul\u00e9s en fonction de la profondeur des TG sont superpos\u00e9es sur les figures suivantes.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-paragraphe\">Capteur T45\u00b0 mono\u00e9l\u00e9ment au contact de 20&#215;22\u00a0mm \u00e0 2,0\u00a0MHz<\/h2>\n<\/p>\n<p>Pour le capteur au contact rectangulaire de 20&#215;22\u00a0mm \u00e0 2,0\u00a0MHz, l\u2019inspection est r\u00e9alis\u00e9e en mode T45\u00b0. Le signal d\u2019entr\u00e9e a une fr\u00e9quence de 2,0\u00a0MHz, une bande passante de 41% et une phase de 75\u00b0.<\/p>\n<\/p>\n<p>La profondeur focale acoustique est de 53\u00a0mm, d\u00e9duite du faisceau simul\u00e9 illustr\u00e9 ci-dessous.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-2.png\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"\" alt=\"\" class=\"mediabox alignnone wp-image-3767\" height=\"202\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-2-small.png\" width=\"200\"><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Les r\u00e9sultats sont <span class=\"g-color2\">\u00e9talonn\u00e9s<\/span> par rapport au TG de \u00d82\u00a0mm \u00e0 52\u00a0mm de profondeur.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-3.png\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"\" alt=\"\" class=\"mediabox alignnone wp-image-3769\" height=\"230\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-3-small.png\" title=\"\" width=\"400\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-3-small.png 400w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-3-small-300x173.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-paragraphe\">CAPTEUR T60\u00b0 MONO\u00c9L\u00c9MENT AU CONTACT DE 20X22\u00a0mm \u00c0 2,0\u00a0MHz<\/h2>\n<\/p>\n<p>Pour le capteur au contact rectangulaire de 20&#215;22\u00a0mm \u00e0 2,0\u00a0MHz, l\u2019inspection est r\u00e9alis\u00e9e en mode T60\u00b0. Le signal d\u2019entr\u00e9e a une fr\u00e9quence de 2,0\u00a0MHz, une bande passante de 40% et une phase de 0\u00b0.<\/p>\n<\/p>\n<p>La profondeur focale acoustique est de 32\u00a0mm, d\u00e9duite du faisceau simul\u00e9 illustr\u00e9 ci-dessous.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-4.png\" title=\"\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" class=\"mediabox alignnone wp-image-3771\" height=\"134\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-4-small.png\" title=\"\" width=\"200\"><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Les r\u00e9sultats sont <span class=\"g-color2\">\u00e9talonn\u00e9s<\/span> par rapport au TG de \u00d82\u00a0mm \u00e0 32\u00a0mm de profondeur.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-5.png\" title=\"\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" class=\"mediabox alignnone wp-image-3773\" height=\"230\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-5-small.png\" title=\"\" width=\"400\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-5-small.png 400w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-5-small-300x173.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Pour ces deux capteurs, les courbes montrent un tr\u00e8s bon accord entre simulation et exp\u00e9rience en champ lointain, et moins de 2\u00a0dB d\u2019\u00e9cart pour des profondeurs de TG comprises entre 0,5 et 1 fois la profondeur focale.<\/p>\n<\/p>\n<p>L\u2019\u00e9cart est un peu plus \u00e9lev\u00e9 en champ proche.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<div class=\"corner-wrapper\">\n<div class=\"corner-frame\"><span class=\"g-color2\">Explications : <\/span>Les \u00e9carts les plus importants se produisent en champ tr\u00e8s proche (jusqu\u2019\u00e0 50% de la profondeur focale). Afin de comprendre le comportement des r\u00e9ponses de ces TG pour les plus petites profondeurs, le champ rayonn\u00e9 dans la pi\u00e8ce a \u00e9t\u00e9 calcul\u00e9 dans plusieurs zones de calcul de champ perpendiculaires \u00e0 l\u2019axe T et positionn\u00e9es le long de cet axe \u00e0 diff\u00e9rentes profondeurs.<\/div>\n<\/div>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-23.png\" title=\"\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" height=\"165\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-23-small.png\" title=\"\" width=\"500\" class=\"alignnone wp-image-3775\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-23-small.png 500w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-23-small-300x99.png 300w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/a><\/p>\n<\/p>\n<p style=\"text-align:center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-24.png\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"\" alt=\"\" height=\"258\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-24-small.png\" title=\"\" width=\"500\" class=\"alignnone wp-image-2855\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-24-small.png 500w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-24-small-300x155.png 300w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Ces r\u00e9sultats de calcul de champ montrent que les interf\u00e9rences entre les ondes planes et les ondes de bord du capteur conduisent \u00e0 des sch\u00e9mas d\u2019interf\u00e9rences observ\u00e9es dans les zones de calcul aux profondeurs les plus petites (inf\u00e9rieure \u00e0 la distance en champ proche du capteur). Ces interf\u00e9rences donnent lieu \u00e0 une plus faible amplitude du champ. Par cons\u00e9quent, les r\u00e9ponses des d\u00e9fauts TG semblent \u00eatre coh\u00e9rentes avec le calcul de champ. Toutefois, le module \u00ab\u00a0R\u00e9ponse D\u00e9faut\u00a0\u00bb est bas\u00e9 sur la simplification du champ rayonn\u00e9 et des ph\u00e9nom\u00e8nes non pris en compte du fait de cette simplification peuvent causer ces \u00e9carts.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-paragraphe\">CAPTEUR MONO\u00c9L\u00c9MENT AU CONTACT DE \u00d812,7\u00a0mm \u00c0 2,25\u00a0MHz<\/h2>\n<\/p>\n<p>Pour le capteur au contact circulaire de \u00d812,7\u00a0mm \u00e0 2,25\u00a0MHz, l\u2019inspection est r\u00e9alis\u00e9e en modes L45\u00b0, L60\u00b0 et T45\u00b0. Le signal d\u2019entr\u00e9e a une fr\u00e9quence de 2,25\u00a0MHz, une bande passante de 50% et une phase de 280\u00b0 pour les ondes L. Pour le mode T45\u00b0, le signal d\u2019entr\u00e9e est exp\u00e9rimental, il correspond \u00e0 l\u2019\u00e9cho sp\u00e9culaire en mode L45\u00b0 g\u00e9n\u00e9r\u00e9 par un TFP de \u00d83\u00a0mm inclin\u00e9 de 45\u00b0 \u00e0 30\u00a0mm de profondeur. Les modes L sont associ\u00e9s \u00e0 des modes T de moindre incidence : T22\u00b0 pour L45\u00b0 et T26\u00b0 pour L60\u00b0.<\/p>\n<\/p>\n<p>Les profondeurs focales acoustiques sont de 8\u00a0mm, 26\u00a0mm, 3\u00a0mm, 15\u00a0mm et 17\u00a0mm respectivement pour les modes L45\u00b0, T22\u00b0, L60\u00b0, T26\u00b0 et T45\u00b0, d\u00e9duites des faisceaux simul\u00e9s illustr\u00e9s ci-dessous.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-6.png\" title=\"\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" class=\"mediabox alignnone wp-image-3778\" height=\"133\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-6-small.png\" title=\"\" width=\"175\"><\/a>; <a align=\"center\" class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-7.png\" title=\"\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" class=\"mediabox alignnone wp-image-3779\" height=\"133\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-7-small.png\" title=\"\" width=\"200\"><\/a> <a align=\"center\" class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-8.png\" title=\"\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" class=\"mediabox alignnone wp-image-3780\" height=\"133\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-8-small.png\" title=\"\" width=\"158\"><\/a> <a align=\"center\" class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-9.png\" title=\"\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" class=\"mediabox alignnone wp-image-3781\" height=\"133\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-9-small.png\" title=\"\" width=\"200\"><\/a> <a align=\"center\" class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-10.png\" title=\"\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" class=\"mediabox alignnone wp-image-3782\" height=\"133\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-10-small.png\" title=\"\" width=\"176\"><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p><span style=\"line-height: 1.5em;\">Les r\u00e9sultats sont respectivement <span class=\"g-color2\">\u00e9talonn\u00e9s<\/span> par rapport au TG de \u00d82\u00a0mm \u00e0 8\u00a0mm, 4\u00a0mm et 20\u00a0mm de profondeur pour les modes L45\u00b0, L60\u00b0 et T45\u00b0.<\/span><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-11.png\" title=\"\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" class=\"mediabox alignnone wp-image-3788\" height=\"200\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-11-small.png\" title=\"\" width=\"350\"><\/a><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-12.png\" title=\"\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" class=\"mediabox alignnone wp-image-3789\" height=\"200\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-12-small.png\" title=\"\" width=\"350\"><\/a><\/p>\n<\/p>\n<p style=\"text-align:center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-13.png\" title=\"\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" class=\"mediabox alignnone wp-image-3792\" height=\"200\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-13-small.png\" title=\"\" width=\"350\"><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Les amplitudes des \u00e9chos issus des ondes L sont bien pr\u00e9dites, l\u2019\u00e9cart maximal \u00e9tant inf\u00e9rieur \u00e0 2\u00a0dB. L\u2019amplitude des \u00e9chos issus des ondes T pr\u00e9sente de plus fortes diff\u00e9rences en champ proche (moins de 5\u00a0dB) mais est souvent correctement estim\u00e9e.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-paragraphe\">CAPTEUR T45\u00b0\u00a0MONO\u00c9L\u00c9MENT AU CONTACT DE\u00a0\u00d86,35\u00a0mm\u00a0\u00c0 2,25\u00a0MHz<\/h2>\n<\/p>\n<p>Pour le capteur au contact circulaire de \u00d86,35\u00a0mm \u00e0 2,25\u00a0MHz, l\u2019inspection est r\u00e9alis\u00e9e en mode T45\u00b0. Le signal d\u2019entr\u00e9e a une fr\u00e9quence de 2,25\u00a0MHz, une bande passante de 44% et une phase de 147\u00b0.<\/p>\n<\/p>\n<p>La profondeur focale acoustique est de 3\u00a0mm, d\u00e9duite du faisceau simul\u00e9 illustr\u00e9 ci-dessous.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-14.png\" title=\"\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" class=\"mediabox alignnone wp-image-3794\" height=\"200\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-14-small.png\" title=\"\" width=\"200\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-14-small.png 200w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-14-small-150x150.png 150w\" sizes=\"auto, (max-width: 200px) 100vw, 200px\" \/><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Les r\u00e9sultats sont <span class=\"g-color2\">\u00e9talonn\u00e9s<\/span> par rapport au TG de \u00d82\u00a0mm SDH \u00e0 4\u00a0mm de profondeur.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-15.png\" title=\"\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" class=\"mediabox alignnone wp-image-3796\" height=\"230\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-15-small.png\" title=\"\" width=\"400\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-15-small.png 400w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-15-small-300x173.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>L\u2019\u00e9cart entre simulation et exp\u00e9rience augmente avec la profondeur des TG mais est toujours inf\u00e9rieur \u00e0 3\u00a0dB, ce qui reste assez bien pr\u00e9dit.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-paragraphe\">CAPTEUR T45\u00b0 MONO\u00c9L\u00c9MENT AU CONTACT DE\u00a0\u00d812,7\u00a0mm\u00a0\u00c0 4,35\u00a0MHz<\/h2>\n<\/p>\n<p>Pour le capteur au contact circulaire de \u00d812,7\u00a0mm \u00e0 4,35\u00a0MHz, l\u2019inspection est r\u00e9alis\u00e9e en mode T45\u00b0. Le signal d\u2019entr\u00e9e a une fr\u00e9quence de 4,35\u00a0MHz, une bande passante de 71% et une phase de 330\u00b0.<\/p>\n<\/p>\n<p>La profondeur focale acoustique est de 31\u00a0mm, d\u00e9duite du faisceau simul\u00e9 illustr\u00e9 ci-dessous.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-16.png\" title=\"\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" class=\"mediabox alignnone wp-image-3798\" height=\"187\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-16-small.png\" title=\"\" width=\"200\"><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Les r\u00e9sultats sont <span class=\"g-color2\">\u00e9talonn\u00e9s <\/span>par rapport au TG de \u00d82\u00a0mm \u00e0 36\u00a0mm de profondeur.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-17.png\" title=\"\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" class=\"mediabox alignnone wp-image-3800\" height=\"230\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-17-small.png\" title=\"\" width=\"400\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-17-small.png 400w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-17-small-300x173.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>On peut remarquer que la courbe des amplitudes simul\u00e9es est plus lisse que la courbe des amplitudes exp\u00e9rimentales, ce qui r\u00e9v\u00e8le probablement une petite incertitude dans les mesures. Malgr\u00e9 tout, l\u2019accord est bon, l\u2019\u00e9cart maximal \u00e9tant de moins de 2\u00a0dB, et m\u00eame de moins de 1\u00a0dB entre 20 et 60\u00a0mm de profondeur.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-paragraphe\">CAPTEUR T45\u00b0 MONO\u00c9L\u00c9MENT AU CONTACT DE\u00a0\u00d86,35\u00a0mm\u00a0\u00c0 4,8\u00a0MHz<\/h2>\n<\/p>\n<p>Pour le capteur au contact circulaire de \u00d86,35\u00a0mm \u00e0 4,8\u00a0MHz, l\u2019inspection est r\u00e9alis\u00e9e en mode T45\u00b0. Le signal d\u2019entr\u00e9e a une fr\u00e9quence de 4,8\u00a0MHz, une bande passante de 45% et une phase de 90\u00b0.<\/p>\n<\/p>\n<p>La profondeur focale acoustique est de 8\u00a0mm, d\u00e9duite du faisceau simul\u00e9 illustr\u00e9 ci-dessous.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-18.png\" title=\"\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" class=\"mediabox alignnone wp-image-3802\" height=\"194\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-18-small.png\" title=\"\" width=\"200\"><\/a><br \/>\n\u00a0<\/p>\n<\/p>\n<p>Les r\u00e9sultats sont <span class=\"g-color2\">\u00e9talonn\u00e9s<\/span> par rapport au TG de \u00d82\u00a0mm \u00e0 8\u00a0mm de profondeur.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-19.png\" title=\"\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" class=\"mediabox alignnone wp-image-3804\" height=\"230\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-19-small.png\" title=\"\" width=\"400\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-19-small.png 400w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-19-small-300x173.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>L\u2019\u00e9cart est, toujours inf\u00e9rieur \u00e0 2\u00a0dB, ce qui montre un bon accord global.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-paragraphe\">CAPTEUR L45\u00b0 MONO\u00c9L\u00c9MENT AU CONTACT DE\u00a0\u00d86,35\u00a0mm\u00a0\u00c0 5,0\u00a0MHz<\/h2>\n<\/p>\n<p>Pour le capteur au contact circulaire de \u00d86,35\u00a0mm \u00e0 5\u00a0MHz, l\u2019inspection est r\u00e9alis\u00e9e en mode L45\u00b0. Le signal d\u2019entr\u00e9e est exp\u00e9rimental, il correspond \u00e0 l\u2019oppos\u00e9 de l\u2019\u00e9cho sp\u00e9culaire en mode L45\u00b0 g\u00e9n\u00e9r\u00e9 par un TFP de \u00d82\u00a0mm inclin\u00e9 de 45\u00b0 \u00e0 8\u00a0mm de profondeur.<\/p>\n<\/p>\n<p>La profondeur focale acoustique est de 3\u00a0mm pour le mode L45\u00b0 et de 12\u00a0mm pour le mode T22\u00b0, d\u00e9duite du faisceau simul\u00e9 illustr\u00e9 ci-dessous.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-20.png\" title=\"\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" class=\"mediabox alignnone wp-image-3806\" height=\"117\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-20-small.png\" title=\"\" width=\"200\"><\/a>\u00a0 \u00a0\u00a0 <a align=\"center\" class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-21.png\" title=\"\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" class=\"mediabox alignnone wp-image-3807\" height=\"117\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-21-small.png\" title=\"\" width=\"200\"><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Les r\u00e9sultats sont <span class=\"g-color2\">\u00e9talonn\u00e9s<\/span> par rapport au TG de \u00d82\u00a0mm \u00e0 4\u00a0mm de profondeur.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-22.png\" title=\"\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" class=\"mediabox alignnone wp-image-3810\" height=\"230\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-22-small.png\" title=\"\" width=\"400\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-22-small.png 400w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TG2-22-small-300x173.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>L\u2019\u00e9cart est inf\u00e9rieur \u00e0 2\u00a0dB pour le faisceau \u00e0 45\u00b0 en champ lointain, l\u2019accord est bon. Dans la zone du champ proche, le mode T associ\u00e9 avec le mode L45\u00b0 est sous-estim\u00e9 par CIVA de 2 \u00e0 4\u00a0dB.<\/p>\n<\/p>\n<p>A 32 et 36\u00a0mm les deux \u00e9chos exp\u00e9rimentaux T22\u00b0 et L45\u00b0 sont l\u00e9g\u00e8rement sous-estim\u00e9s car ces TG sont ab\u00eem\u00e9s par la rouille. Cette cale a d\u2019ailleurs \u00e9t\u00e9 remplac\u00e9e pour les cas de validation exp\u00e9rimentale.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-accordeon\">conclusion<\/h2>\n<\/p>\n<p>Les r\u00e9sultats montrent un bon accord avec g\u00e9n\u00e9ralement moins de 2\u00a0dB d\u2019\u00e9cart pour tous les capteurs mono-\u00e9l\u00e9ments au contact. Pour un capteur donn\u00e9, un \u00e9cho de TG obtenu pour un mode donn\u00e9 peut \u00eatre utilis\u00e9 comme \u00e9cho d\u2019\u00e9talonnage en amplitude pour tous les autres modes g\u00e9n\u00e9r\u00e9s par le m\u00eame capteur. Et les amplitudes relatives de ces \u00e9chos sp\u00e9culaires L et T des TG aux diff\u00e9rentes profondeurs sont en tr\u00e8s bon accord.<\/p>\n<\/p>\n<p>En champ proche les \u00e9carts sont l\u00e9g\u00e8rement plus importants. Ceci est d\u00fb \u00e0 des limitations du mod\u00e8le et sera expliqu\u00e9 plus en d\u00e9tails pour les capteurs rectangulaires au contact.<\/p>\n<\/p>\n<p>L\u2019hypoth\u00e8se de forme d\u2019onde non d\u00e9form\u00e9e par le d\u00e9faut, utilis\u00e9e par les mod\u00e8les de CIVA, est g\u00e9n\u00e9ralement valable en champ lointain ou dans la zone focale, mais beaucoup moins en champ proche, ce qui conduit \u00e0 des divergences (moins de 5\u00a0dB) lorsque l\u2019on consid\u00e8re des TG en champ proche voire tr\u00e8s proche (de 0 \u00e0 50% de la profondeur focale).<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Continuer vers <a class=\"lien\" href=\"https:\/\/www.extende.com\/fr\/la-simulation-cnd\/documentation\/validation-experimentale-des-modeles-civa\/validation-experimentale-des-modeles-civa-en-ultrasons\/ultrasons-reflecteurs-artificiels\/reflecteurs-generatrices\/ut-reflecteurs-generatrices-trous-generatrices-et-capteurs-multielements-au-contact\/\" target=\"_self\">Trous g\u00e9n\u00e9ratrices et capteurs multi\u00e9l\u00e9ment au contact<\/a><\/p>\n<\/p>\n<p>Retourner au menu <a class=\"lien\" href=\"https:\/\/www.extende.com\/fr\/la-simulation-cnd\/documentation\/validation-experimentale-des-modeles-civa\/validation-experimentale-des-modeles-civa-en-ultrasons\/ultrasons-reflecteurs-artificiels\/reflecteurs-generatrices\/\" target=\"_self\">R\u00e9flecteurs g\u00e9n\u00e9ratrices<\/a><\/p>\n<\/p>\n<p>Retourner au menu <a class=\"lien\" href=\"https:\/\/www.extende.com\/fr\/la-simulation-cnd\/documentation\/validation-experimentale-des-modeles-civa\/validation-experimentale-des-modeles-civa-en-ultrasons\/ultrasons-reflecteurs-artificiels\/\" target=\"_self\">R\u00e9flecteurs artificiels<\/a><\/p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Validation exp\u00e9rimentale et caract\u00e9risation des mod\u00e8les Ultrasons de CIVA, r\u00e9flecteurs artificiels, g\u00e9n\u00e9ratrices, logiciel de simulation CND<\/p>\n","protected":false},"author":0,"featured_media":0,"parent":2934,"menu_order":1,"comment_status":"closed","ping_status":"closed","template":"templates\/page--extende.html.php","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-3812","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.extende.com\/fr\/wp-json\/wp\/v2\/pages\/3812","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.extende.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.extende.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"replies":[{"embeddable":true,"href":"https:\/\/www.extende.com\/fr\/wp-json\/wp\/v2\/comments?post=3812"}],"version-history":[{"count":1,"href":"https:\/\/www.extende.com\/fr\/wp-json\/wp\/v2\/pages\/3812\/revisions"}],"predecessor-version":[{"id":5616,"href":"https:\/\/www.extende.com\/fr\/wp-json\/wp\/v2\/pages\/3812\/revisions\/5616"}],"up":[{"embeddable":true,"href":"https:\/\/www.extende.com\/fr\/wp-json\/wp\/v2\/pages\/2934"}],"wp:attachment":[{"href":"https:\/\/www.extende.com\/fr\/wp-json\/wp\/v2\/media?parent=3812"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}