{"id":3922,"date":"2025-06-24T18:36:08","date_gmt":"2025-06-24T16:36:08","guid":{"rendered":""},"modified":"2025-06-24T18:52:12","modified_gmt":"2025-06-24T16:52:12","slug":"ut-reflecteurs-trous-a-fond-plat-tfp-a-differentes-profondeurs","status":"publish","type":"page","link":"https:\/\/www.extende.com\/fr\/la-simulation-cnd\/documentation\/validation-experimentale-des-modeles-civa\/validation-experimentale-des-modeles-civa-en-ultrasons\/ultrasons-reflecteurs-artificiels\/reflecteurs-trous-a-fond-plat\/ut-reflecteurs-trous-a-fond-plat-tfp-a-differentes-profondeurs\/","title":{"rendered":"UT &#8211; R\u00e9flecteurs Trous \u00e0 Fond Plat &#8211; TFP \u00e0 diff\u00e9rentes profondeurs"},"content":{"rendered":"<p>Vue globale (C=Contact ; I=Immersion):<\/p>\n<\/p>\n<div style=\"text-align:center;\">\n<table border=\"1\" cellpadding=\"2\" cellspacing=\"0\" style=\"line-height: 18px; text-align: center;\">\n<tbody>\n<tr>\n<td>Capteur<\/td>\n<td>2,0\u00a0MHz 20*22\u00a0mm<\/td>\n<td>5,0\u00a0MHz \u00d86,35\u00a0mm<\/td>\n<td>2,0\u00a0MHz \u00d812,7\u00a0mm<\/td>\n<td>2,25\u00a0MHz \u00d812,7\u00a0mm<\/td>\n<td>5,0\u00a0MHz \u00d812,7\u00a0mm<\/td>\n<td>2,25\u00a0MHz \u00d819\u00a0mm<\/td>\n<td>5,0\u00a0MHz \u00d819\u00a0mm<\/td>\n<\/tr>\n<tr>\n<td>L0\u00b0<\/td>\n<td>\u00a0<\/td>\n<td>I<\/td>\n<td>\u00a0<\/td>\n<td>I<\/td>\n<td>I<\/td>\n<td>I<\/td>\n<td>I<\/td>\n<\/tr>\n<tr>\n<td>L45\u00b0<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td>C<\/td>\n<td>I<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>T45\u00b0<\/td>\n<td>C<\/td>\n<td>\u00a0<\/td>\n<td>C<\/td>\n<td>I<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-accordeon\">CONFIGURATION<\/h2>\n<\/p>\n<p>Des mesures exp\u00e9rimentales ont \u00e9t\u00e9 r\u00e9alis\u00e9es en ondes<span class=\"g-color2\"> L0\u00b0<\/span>, <span class=\"g-color2\">L45\u00b0<\/span> et <span class=\"g-color2\">T45<\/span>\u00b0 sur deux pi\u00e8ces de surface plane contenant une s\u00e9rie de TFP de diam\u00e8tres \u00d81\u00a0mm, 3\u00a0mm et 6\u00a0mm \u00e0 diff\u00e9rentes profondeurs (de 5 \u00e0 60\u00a0mm par pas de 5\u00a0mm puis \u00e0 80, 100, 125 et 150\u00a0mm). Pour l\u2019inspection en L0\u00b0, les TFP sont verticaux, tandis que pour l\u2019\u00e9tude en L45\u00b0 et T45\u00b0 ils sont inclin\u00e9s de 45\u00b0. Les deux pi\u00e8ces et les d\u00e9fauts sont repr\u00e9sent\u00e9s ci-dessous.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align: center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-1.png\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"middle\" alt=\"\" class=\"mediabox alignnone wp-image-2820\" height=\"279\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-1-small.png\" width=\"300\"><\/a><\/p>\n<\/p>\n<p style=\"text-align: center;\"><span class=\"couleur3\"><em>Pi\u00e8ce contenant des TFP verticaux pour l&rsquo;inspection en L0\u00b0<\/em><\/span><\/p>\n<\/p>\n<p style=\"text-align: center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-2.png\" style=\"text-decoration: none; text-align: start;\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"middle\" alt=\"\" class=\"mediabox alignnone wp-image-2835\" height=\"184\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-2-small.png\" width=\"300\"><\/a><\/p>\n<\/p>\n<p style=\"text-align: center;\"><span class=\"couleur3\"><em>Pi\u00e8ce contenant des TFP inclin\u00e9s \u00e0 45\u00b0 pour l&rsquo;inspection en L45\u00b0 et T45\u00b0<\/em><\/span><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<div class=\"corner-wrapper\">\n<div class=\"corner-frame\">Remarque : des inspections ont mis en \u00e9vidence un probl\u00e8me d\u2019inhomog\u00e9n\u00e9it\u00e9 de l\u2019acier ferritique constituant les maquettes. Cette h\u00e9t\u00e9rog\u00e9n\u00e9it\u00e9 se traduit par des petites irr\u00e9gularit\u00e9s sur certaines courbes de mesures exp\u00e9rimentales.<\/div>\n<\/div>\n<p><span style=\"line-height: 1.5em;\">Pour chaque capteur une inspection est r\u00e9alis\u00e9e sur la surface du bloc et un C-scan est obtenu. Sur l\u2019image C-scan suivante correspondant aux TFP de \u00d86\u00a0mm, l\u2019\u00e9cho de fond a \u00e9t\u00e9 masqu\u00e9 de mani\u00e8re \u00e0 mettre en avant les \u00e9chos de TFP. Cependant, sur l\u2019image B-scan suivante extraite sur une ligne, on visualise les \u00e9chos de TFP et l\u2019\u00e9cho de fond.<\/span><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align: center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-3.png\" style=\"text-decoration: none;\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"middle\" alt=\"\" class=\"mediabox alignnone wp-image-3880\" height=\"272\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-3-small.png\" width=\"500\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-3-small.png 500w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-3-small-300x163.png 300w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Pour chaque trou l\u2019amplitude maximale de l\u2019\u00e9cho sp\u00e9culaire est mesur\u00e9e relativement \u00e0 un trou d\u2019\u00e9talonnage. Le mod\u00e8le d\u2019interaction utilis\u00e9 est le mod\u00e8le de <span class=\"g-color2\">Kirchhoff<\/span>, celui-ci \u00e9tant adapt\u00e9 aux \u00e9chos sp\u00e9culaires.\u00a0<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Les capteurs <span class=\"g-color2\">au contact<\/span> suivants ont \u00e9t\u00e9 \u00e9tudi\u00e9s :<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<div style=\"text-align:center;\">\n<table border=\"1\" cellpadding=\"2\" cellspacing=\"0\" style=\"line-height: 18px; text-align: center;\">\n<tbody>\n<tr>\n<td>Fr\u00e9quence<\/td>\n<td>Pastille<\/td>\n<td>Mode<\/td>\n<td>D\u00e9faut d&rsquo;\u00e9talonnage<\/td>\n<td>Profondeur d&rsquo;\u00e9talonnage<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">2,0\u00a0MHz<\/td>\n<td>20&#215;22\u00a0mm<\/td>\n<td>T45\u00b0<\/td>\n<td>TFP de \u00d83\u00a0mm<\/td>\n<td>80\u00a0mm<\/td>\n<\/tr>\n<tr>\n<td>\u00d812,7\u00a0mm<\/td>\n<td>T45\u00b0<\/td>\n<td>TG de \u00d82\u00a0mm<\/td>\n<td>20\u00a0mm<\/td>\n<\/tr>\n<tr>\n<td>2,25\u00a0MHz<\/td>\n<td>\u00d812,7\u00a0mm<\/td>\n<td>L45\u00b0<\/td>\n<td>TG de \u00d82\u00a0mm<\/td>\n<td>8\u00a0mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>\u00a0<\/p>\n<\/p>\n<p><span style=\"line-height: 1.5em;\">Les capteurs <span class=\"g-color2\">en immersion<\/span> suivants ont \u00e9t\u00e9 \u00e9tudi\u00e9s.<\/span><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<div style=\"text-align:center;\">\n<table border=\"1\" cellpadding=\"2\" cellspacing=\"0\" style=\"line-height: 18px;\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\">Fr\u00e9quence<\/td>\n<td style=\"text-align: center;\">Pastille<\/td>\n<td style=\"text-align: center;\">Mode<\/td>\n<td style=\"text-align: center;\">D\u00e9faut d&rsquo;\u00e9talonnage<\/td>\n<td>Profondeur d&rsquo;\u00e9talonnage<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" style=\"text-align: center;\">2,25\u00a0MHz<\/td>\n<td rowspan=\"2\" style=\"text-align: center;\">\u00d812,7\u00a0mm<\/td>\n<td style=\"text-align: center;\">L0\u00b0<\/td>\n<td style=\"text-align: center;\">TG de \u00d82\u00a0mm<\/td>\n<td style=\"text-align: center;\">12\u00a0mm<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">T45\u00b0<\/td>\n<td style=\"text-align: center;\">TG de \u00d82\u00a0mm<\/td>\n<td style=\"text-align: center;\">12\u00a0mm<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">\u00d819\u00a0mm<\/td>\n<td style=\"text-align: center;\">L0\u00b0<\/td>\n<td style=\"text-align: center;\">TG de \u00d82\u00a0mm<\/td>\n<td style=\"text-align: center;\">24\u00a0mm<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" style=\"text-align: center;\">4,6\u00a0MHz<\/td>\n<td rowspan=\"2\" style=\"text-align: center;\">\u00d812,7\u00a0mm<\/td>\n<td style=\"text-align: center;\">L0\u00b0<\/td>\n<td style=\"text-align: center;\">TG de \u00d82\u00a0mm<\/td>\n<td style=\"text-align: center;\">24\u00a0mm<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">\u00d812,7\u00a0mm<\/td>\n<td style=\"text-align: center;\">TG de \u00d82\u00a0mm<\/td>\n<td style=\"text-align: center;\">24\u00a0mm<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">\u00d819\u00a0mm<\/td>\n<td style=\"text-align: center;\">L0\u00b0<\/td>\n<td style=\"text-align: center;\">TG de \u00d82\u00a0mm<\/td>\n<td style=\"text-align: center;\">60\u00a0mm<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">5,0\u00a0MHz<\/td>\n<td style=\"text-align: center;\">\u00d86,35\u00a0mm<\/td>\n<td style=\"text-align: center;\">L0\u00b0<\/td>\n<td style=\"text-align: center;\">TG de \u00d82\u00a0mm<\/td>\n<td style=\"text-align: center;\">8\u00a0mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>\u00a0<\/p>\n<\/p>\n<p><span style=\"line-height: 1.5em;\"><\/span><\/p>\n<\/p>\n<h2 class=\"titre-accordeon\">R\u00c9SULTATS<\/h2>\n<\/p>\n<p><span style=\"line-height: 1.5em;\"><\/span><\/p>\n<\/p>\n<p>L\u2019amplitude maximale de l\u2019\u00e9cho sp\u00e9culaire sur le TFP est estim\u00e9e relativement \u00e0 un r\u00e9flecteur d\u2019\u00e9talonnage. Les courbes DGS suivantes sont affich\u00e9es pour tous les capteurs \u00e0 partir de donn\u00e9es simul\u00e9es, mesur\u00e9es ou issues de la litt\u00e9rature.<\/p>\n<\/p>\n<p>Les r\u00e9sultats pr\u00e9sentent un bon accord dans la plupart des cas.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-paragraphe\">Capteur T45\u00b0 mono\u00e9l\u00e9ment au contact \u00e0 2,0\u00a0MHz et de dimension 20&#215;22\u00a0mm<\/h2>\n<\/p>\n<p><span style=\"line-height: 1.5em;\">Pour le capteur au contact de 20&#215;22\u00a0mm \u00e0 2\u00a0MHz, l\u2019inspection est r\u00e9alis\u00e9e avec le mode T45\u00b0. Le signal d\u2019entr\u00e9e a une fr\u00e9quence de 2\u00a0MHz, une bande passante de 41% et une phase de 75\u00b0.<\/span><\/p>\n<\/p>\n<p>La profondeur focale acoustique est de 53\u00a0mm, d\u00e9duite du faisceau simul\u00e9 illustr\u00e9 ci-dessous.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align: center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-4.png\" style=\"text-decoration: none;\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"middle\" alt=\"\" class=\"mediabox alignnone wp-image-3882\" height=\"202\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-4-small.png\" width=\"200\"><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Les r\u00e9sultats sont \u00e9talonn\u00e9s par rapport au TFP de \u00d83\u00a0mm \u00e0 80\u00a0mm de profondeur.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align: center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-5.png\" style=\"text-decoration: none; text-align: start;\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"middle\" alt=\"\" class=\"mediabox alignnone wp-image-3884\" height=\"230\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-5-small.png\" width=\"400\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-5-small.png 400w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-5-small-300x173.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Un bon accord est observable avec g\u00e9n\u00e9ralement moins de 2\u00a0dB d\u2019\u00e9cart. Pour les trous petits et peu profonds, CIVA sous-estime l\u00e9g\u00e8rement l\u2019amplitude des \u00e9chos. Les courbes exp\u00e9rimentales repr\u00e9sentant les amplitudes relatives des \u00e9chos de TFP en fonction de leur profondeur sont moins lisses que les courbes simul\u00e9es. Cette irr\u00e9gularit\u00e9 est due \u00e0 l\u2019h\u00e9t\u00e9rog\u00e9n\u00e9it\u00e9 du mat\u00e9riau.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-paragraphe\">Capteur T45\u00b0 mono\u00e9l\u00e9ment au contact \u00e0 2,0\u00a0MHz et de \u00d812,7\u00a0mm<\/h2>\n<\/p>\n<p><span style=\"line-height: 1.5em;\">Pour le capteur au contact circulaire de \u00d812,7\u00a0mm \u00e0 2\u00a0MHz, l\u2019inspection est r\u00e9alis\u00e9e avec le mode T45\u00b0. Le signal d\u2019entr\u00e9e est l\u2019oppos\u00e9 d\u2019un \u00e9cho sp\u00e9culaire direct obtenu exp\u00e9rimentalement en ondes L45\u00b0 sur un TFP de \u00d83\u00a0mm inclin\u00e9 de 45\u00b0 \u00e0 30\u00a0mm de profondeur.<\/span><\/p>\n<\/p>\n<p>La profondeur focale acoustique est de 17\u00a0mm, d\u00e9duite du faisceau simul\u00e9 illustr\u00e9 ci-dessous.\u00a0<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<div style=\"text-align: center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-6.png\" style=\"text-decoration: none; line-height: 1.5em;\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"middle\" alt=\"\" class=\"mediabox alignnone wp-image-3886\" height=\"151\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-6-small.png\" width=\"200\"><\/a><span style=\"line-height: 1.5em;\">\u00a0\u00a0<\/span><\/div>\n<\/p>\n<p>\nLes r\u00e9sultats sont \u00e9talonn\u00e9s par rapport au TG de \u00d82\u00a0mm \u00e0 20\u00a0mm de profondeur inspect\u00e9s dans un autre bloc en ondes T45\u00b0.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align: center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-7.png\" style=\"text-decoration: none; text-align: start;\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"middle\" alt=\"\" class=\"mediabox alignnone wp-image-3888\" height=\"230\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-7-small.png\" width=\"400\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-7-small.png 400w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-7-small-300x173.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Bien que les courbes simul\u00e9es par CIVA soient plus lisses (h\u00e9t\u00e9rog\u00e9n\u00e9it\u00e9 de l\u2019acier), un bon accord est observable entre simulation et mesure pour les TFP de \u00d81\u00a0mm et de \u00d86\u00a0mm. CIVA surestime l\u2019\u00e9cho des TFP de \u00d83\u00a0mm profonds, de 2\u00a0dB \u00e0 60\u00a0mm \u00e0 6\u00a0dB \u00e0 150\u00a0mm.<\/p>\n<\/p>\n<p>\nEn plus du bon accord mesure \/ simulation obtenu pour les amplitudes, un tr\u00e8s bon accord est obtenu pour les formes des \u00e9chos.<\/p>\n<\/p>\n<p>Sur les courbes suivantes, les \u00e9chos sp\u00e9culaires directs simul\u00e9s (rouge) et mesur\u00e9s (noir) sont superpos\u00e9s pour plusieurs TFP de \u00d86\u00a0mm \u00e0 diff\u00e9rentes profondeurs inspect\u00e9s avec ce capteur T45\u00b0 au contact de \u00d812,7\u00a0mm \u00e0 2\u00a0MHz.\u00a0<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<div style=\"text-align: center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-8.png\" style=\"text-decoration: none; line-height: 1.5em;\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"middle\" alt=\"\" class=\"mediabox alignnone wp-image-3890\" height=\"198\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-8.png\" width=\"500\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-8.png 870w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-8-300x119.png 300w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-8-768x305.png 768w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-8-600x238.png 600w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/a><span style=\"line-height: 1.5em;\">\u00a0\u00a0<\/span><\/div>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-paragraphe\">Capteur L45\u00b0 mono-\u00e9l\u00e9ment au contact\u00a0\u00a0\u00e0 2,25\u00a0MHz et de \u00d812,7\u00a0mm<\/h2>\n<\/p>\n<p><span style=\"line-height: 1.5em;\">Pour le capteur au contact circulaire de \u00d812,7\u00a0mm \u00e0 2,25\u00a0MHz, l\u2019inspection est r\u00e9alis\u00e9e avec le mode L45\u00b0. Le signal d\u2019entr\u00e9e a une fr\u00e9quence de 2,25\u00a0MHz, une bande passante de 50% et une phase de 280\u00b0.<\/span><\/p>\n<\/p>\n<p>La profondeur focale acoustique est de 8\u00a0mm, d\u00e9duite du faisceau simul\u00e9 illustr\u00e9 ci-dessous.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align: center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-9.png\" style=\"text-decoration: none; text-align: start;\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"middle\" alt=\"\" class=\"mediabox alignnone wp-image-3891\" height=\"152\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-9-small.png\" width=\"200\"><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Les r\u00e9sultats sont \u00e9talonn\u00e9s par rapport au TG de \u00d82\u00a0mm \u00e0 8\u00a0mm de profondeur inspect\u00e9 dans un autre bloc en ondes T45\u00b0.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align: center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-10.png\" style=\"text-decoration: none; text-align: start;\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"middle\" alt=\"\" class=\"mediabox alignnone wp-image-3893\" height=\"230\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-10-small.png\" width=\"400\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-10-small.png 400w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-10-small-300x173.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Les courbes affichent un bon accord entre simulation et exp\u00e9rience avec moins de 2\u00a0dB d\u2019\u00e9cart pour les 3 tailles de TFP. Les courbes exp\u00e9rimentales sont moins lisses que les courbes issues de la simulation \u00e0 cause de l\u2019h\u00e9t\u00e9rog\u00e9n\u00e9it\u00e9 de l\u2019acier.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-paragraphe\">Capteur L0\u00b0 en immersion mono-\u00e9l\u00e9ment \u00e0 2,25\u00a0MHz de \u00d812,7\u00a0mm\u00a0<\/h2>\n<\/p>\n<p><span style=\"line-height: 1.5em;\">Pour le capteur en immersion circulaire de \u00d812,7\u00a0mm \u00e0 2,25\u00a0MHz, l\u2019inspection est r\u00e9alis\u00e9e avec le mode L0\u00b0 pour une hauteur d\u2019eau de 50\u00a0mm. Le signal d\u2019entr\u00e9e a une fr\u00e9quence de 2,25\u00a0MHz, une bande passante de 60% et une phase de 0\u00b0.<\/span><\/p>\n<\/p>\n<p>La profondeur focale acoustique est de 4\u00a0mm, d\u00e9duite du faisceau simul\u00e9 illustr\u00e9 ci-dessous.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align: center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-11.png\" style=\"text-decoration: none; text-align: start;\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"middle\" alt=\"\" class=\"mediabox alignnone wp-image-3895\" height=\"200\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-11-small.png\" width=\"200\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-11-small.png 200w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-11-small-150x150.png 150w\" sizes=\"auto, (max-width: 200px) 100vw, 200px\" \/><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Les r\u00e9sultats sont \u00e9talonn\u00e9s par rapport au TG de \u00d82\u00a0mm \u00e0 12\u00a0mm de profondeur inspect\u00e9 dans un autre bloc en ondes L0\u00b0.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align: center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-12.png\" style=\"text-decoration: none; text-align: start;\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"middle\" alt=\"\" class=\"mediabox alignnone wp-image-3897\" height=\"230\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-12-small.png\" width=\"400\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-12-small.png 400w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-12-small-300x173.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Les courbes affichent un bon accord entre simulation et exp\u00e9rience avec moins de 2\u00a0dB d\u2019\u00e9cart pour les 3 tailles de TFP.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-paragraphe\">Capteur T45\u00b0 mono-\u00e9l\u00e9ment en immersion\u00a0\u00e0 2,25\u00a0MHz et de \u00d812,7\u00a0mm\u00a0<\/h2>\n<\/p>\n<p>Pour le capteur en immersion circulaire de \u00d812,7\u00a0mm \u00e0 2,25\u00a0MHz, l\u2019inspection est r\u00e9alis\u00e9e avec le mode T45\u00b0 pour une hauteur d\u2019eau de 50\u00a0mm. Le signal d\u2019entr\u00e9e a une fr\u00e9quence de 2,25\u00a0MHz, une bande passante de 60% et une phase de 0\u00b0.<\/p>\n<\/p>\n<p><span style=\"line-height: 1.5em;\">La profondeur focale acoustique est de 4\u00a0mm, d\u00e9duite du faisceau simul\u00e9 illustr\u00e9 ci-dessous.<\/span><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align: center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-13.png\" style=\"text-decoration: none; text-align: start;\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"middle\" alt=\"\" class=\"mediabox alignnone wp-image-3899\" height=\"161\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-13-small.png\" width=\"200\"><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Les r\u00e9sultats sont \u00e9talonn\u00e9s par rapport au TG de \u00d82\u00a0mm \u00e0 12\u00a0mm de profondeur inspect\u00e9 dans un autre bloc en ondes L0\u00b0.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align: center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-14.png\" style=\"text-decoration: none; text-align: start;\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"middle\" alt=\"\" class=\"mediabox alignnone wp-image-3901\" height=\"230\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-14-small.png\" width=\"400\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-14-small.png 400w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-14-small-300x173.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/a><\/p>\n<\/p>\n<p style=\"text-align: justify;\">\u00a0<\/p>\n<\/p>\n<p style=\"text-align: justify;\"><span style=\"text-align: start;\">Les courbes affichent un bon accord entre simulation et exp\u00e9rience avec moins de 2\u00a0dB d\u2019\u00e9cart pour les 3 tailles de TFP. Les courbes exp\u00e9rimentales sont moins lisses que les courbes issues de la simulation, toujours \u00e0 cause de l\u2019h\u00e9t\u00e9rog\u00e9n\u00e9it\u00e9 de l\u2019acier.\u00a0<\/span><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-paragraphe\">Capteur L0\u00b0 en immersion mono-\u00e9l\u00e9ment \u00e0 2,25\u00a0MHz de \u00d819\u00a0mm \u00a0<\/h2>\n<\/p>\n<p><span style=\"line-height: 1.5em;\">Pour le capteur en immersion circulaire de \u00d819\u00a0mm \u00e0 2,25\u00a0MHz, l\u2019inspection est r\u00e9alis\u00e9e avec le mode L0\u00b0 pour une hauteur d\u2019eau de 50\u00a0mm. Le signal d\u2019entr\u00e9e a une fr\u00e9quence de 2,25\u00a0MHz, une bande passante de 60% et une phase de 0\u00b0.<\/span><\/p>\n<\/p>\n<p>La profondeur focale acoustique est de 18\u00a0mm, d\u00e9duite du faisceau simul\u00e9 illustr\u00e9 ci-dessous.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align: center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-15-small.png\" style=\"text-decoration: none; text-align: start;\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"middle\" alt=\"\" class=\"mediabox alignnone wp-image-3903\" height=\"200\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-15-small.png\" width=\"200\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-15-small.png 200w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-15-small-150x150.png 150w\" sizes=\"auto, (max-width: 200px) 100vw, 200px\" \/><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Les r\u00e9sultats sont \u00e9talonn\u00e9s par rapport au TG de \u00d82\u00a0mm \u00e0 24\u00a0mm de profondeur inspect\u00e9 dans un autre bloc en ondes L0\u00b0.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align: center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-16.png\" style=\"text-decoration: none;\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"middle\" alt=\"\" class=\"mediabox alignnone wp-image-3904\" height=\"230\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-16-small.png\" width=\"400\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-16-small.png 400w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-16-small-300x173.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Un bon accord entre simulation et exp\u00e9rience s\u2019observeavec moins de 2\u00a0dB d\u2019\u00e9cart pour les TFP de 3 et 6\u00a0mm. Pour les TFP de 1\u00a0mm, des \u00e9carts de 3 et 4\u00a0dB s\u2019affichent pour des profondeurs sup\u00e9rieures \u00e0 50\u00a0mm.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-paragraphe\">Capteur L0\u00b0 en immersion mono-\u00e9l\u00e9ment \u00e0 4,6\u00a0MHz de \u00d812,7\u00a0mm<\/h2>\n<\/p>\n<div><span style=\"line-height: 1.5em;\">Pour le capteur en immersion circulaire de \u00d812,7\u00a0mm \u00e0 4,6\u00a0MHz, l\u2019inspection est r\u00e9alis\u00e9e avec le mode L0\u00b0 pour une hauteur d\u2019eau de 50\u00a0mm. Le signal d\u2019entr\u00e9e a une fr\u00e9quence de 4,6\u00a0MHz, une bande passante de 65% et une phase de 220\u00b0.<\/span><\/div>\n<\/p>\n<p>La profondeur focale acoustique est de 19\u00a0mm, d\u00e9duite du faisceau simul\u00e9 illustr\u00e9 ci-dessous.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align: center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-17-large.png\" style=\"text-decoration: none;\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"middle\" alt=\"\" class=\"mediabox alignnone wp-image-3906\" height=\"170\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-17.png\" width=\"170\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-17.png 170w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-17-150x150.png 150w\" sizes=\"auto, (max-width: 170px) 100vw, 170px\" \/><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Les r\u00e9sultats sont \u00e9talonn\u00e9s par rapport au TG de \u00d82\u00a0mm \u00e0 24\u00a0mm de profondeur inspect\u00e9 dans un autre bloc en ondes L0\u00b0.\u00a0<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align: center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-18.png\" style=\"text-decoration: none; line-height: 1.5em;\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"middle\" alt=\"\" class=\"mediabox alignnone wp-image-3908\" height=\"230\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-18-small.png\" width=\"400\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-18-small.png 400w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-18-small-300x173.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/a>\u00a0<\/p>\n<\/p>\n<p>\nPour des profondeurs sup\u00e9rieures \u00e0 20\u00a0mm, les courbes affichent un bon accord entre simulation et exp\u00e9rience avec moins de 2\u00a0dB d\u2019\u00e9cart pour les 3 tailles de TFP. Pour des profondeurs inf\u00e9rieures \u00e0 la profondeur focale, les \u00e9carts atteignent 4\u00a0dB, ce qui peut s\u2019expliquer par la <a class=\"lien\" href=\"https:\/\/www.extende.com\/fr\/la-simulation-cnd\/documentation\/validation-experimentale-des-modeles-civa\/validation-experimentale-des-modeles-civa-en-ultrasons\/ultrasons-reflecteurs-artificiels\/reflecteurs-trous-a-fond-plat\/ut-reflecteurs-trous-a-fond-plat-conclusion-et-discussion-sur-les-limitations\/\" target=\"_self\">limitation de champ proche<\/a> des mod\u00e8les de CIVA.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-paragraphe\">Capteur L45\u00b0 en immersion mono-\u00e9l\u00e9ment \u00e0 4,6\u00a0MHz de \u00d812,7\u00a0mm<\/h2>\n<\/p>\n<p><span style=\"line-height: 1.5em;\">Pour le capteur en immersion circulaire de \u00d812,7\u00a0mm \u00e0 4,6\u00a0MHz, l\u2019inspection est r\u00e9alis\u00e9e avec le mode L45\u00b0 pour une hauteur d\u2019eau de 50\u00a0mm. Le signal d\u2019entr\u00e9e a une fr\u00e9quence de 4,6\u00a0MHz, une bande passante de 65% et une phase de 220\u00b0.<\/span><\/p>\n<\/p>\n<p>La profondeur focale acoustique est de 10\u00a0mm, d\u00e9duite du faisceau simul\u00e9 illustr\u00e9 ci-dessous.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align: center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-19.png\" style=\"text-decoration: none;\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"middle\" alt=\"\" class=\"mediabox alignnone wp-image-3910\" height=\"149\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-19-small.png\" width=\"200\"><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Les r\u00e9sultats sont \u00e9talonn\u00e9s par rapport au TG de \u00d82\u00a0mm \u00e0 24\u00a0mm de profondeur inspect\u00e9 dans un autre bloc en ondes L0\u00b0.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align: center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-20.png\" style=\"text-decoration: none;\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"middle\" alt=\"\" class=\"mediabox alignnone wp-image-3912\" height=\"230\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-20-small.png\" width=\"400\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-20-small.png 400w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-20-small-300x173.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Les courbes affichent un bon accord entre simulation et exp\u00e9rience avec moins de 2\u00a0dB d\u2019\u00e9cart pour les 3 tailles de TFP sauf pour le TFP de 1\u00a0mm \u00e0 45\u00a0mm de profondeur pour lequel la courbe exp\u00e9rimentale est moins lisse que celle de simulation (h\u00e9t\u00e9rog\u00e9n\u00e9it\u00e9 de l\u2019acier), et l\u2019\u00e9cart atteint 4\u00a0dB.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-paragraphe\">Capteur L0\u00b0 en immersion mono-\u00e9l\u00e9ment \u00e0 4,6\u00a0MHz de \u00d819\u00a0mm<\/h2>\n<\/p>\n<div><span style=\"line-height: 1.5em;\">Pour le capteur en immersion circulaire de \u00d819\u00a0mm \u00e0 4,6\u00a0MHz, l\u2019inspection est r\u00e9alis\u00e9e avec le mode L0\u00b0 pour une hauteur d\u2019eau de 50\u00a0mm. Le signal d\u2019entr\u00e9e a une fr\u00e9quence de 4,6\u00a0MHz, une bande passante de 60% et une phase de 20\u00b0.<\/span><\/div>\n<\/p>\n<p>La profondeur focale acoustique est de 55\u00a0mm, d\u00e9duite du faisceau simul\u00e9 illustr\u00e9 ci-dessous.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align: center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-21.png\" style=\"text-decoration: none;\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"middle\" alt=\"\" class=\"mediabox alignnone wp-image-3914\" height=\"238\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-21-small.png\" width=\"200\"><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Les r\u00e9sultats sont \u00e9talonn\u00e9s par rapport au TG de \u00d82\u00a0mm \u00e0 60\u00a0mm de profondeur inspect\u00e9 dans un autre bloc en ondes L0\u00b0.\u00a0<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<div style=\"text-align: center;\"><span style=\"line-height: 1.5em;\">\u00a0\u00a0<\/span><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-22.png\" style=\"text-decoration: none; line-height: 1.5em;\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"middle\" alt=\"\" class=\"mediabox alignnone wp-image-3916\" height=\"230\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-22-small.png\" width=\"400\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-22-small.png 400w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-22-small-300x173.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/a><\/div>\n<\/p>\n<div style=\"text-align: center;\">\u00a0<\/div>\n<\/p>\n<p>Les courbes des TFP de 3 et 6\u00a0mm affichent un bon accord entre simulation et exp\u00e9rience avec moins de 2\u00a0dB d\u2019\u00e9cart surtout pour des profondeurs sup\u00e9rieures \u00e0 45\u00a0mm. En revanche, pour les TFP de 1\u00a0mm, on observe des \u00e9carts atteignant 6\u00a0dB. Cet \u00e9cart est probablement d\u00fb \u00e0 la <a class=\"lien\" href=\"https:\/\/www.extende.com\/fr\/la-simulation-cnd\/documentation\/validation-experimentale-des-modeles-civa\/validation-experimentale-des-modeles-civa-en-ultrasons\/ultrasons-reflecteurs-artificiels\/reflecteurs-trous-a-fond-plat\/ut-reflecteurs-trous-a-fond-plat-conclusion-et-discussion-sur-les-limitations\/\" target=\"_self\">limitation \u00ab petits d\u00e9fauts \u00bb<\/a> du mod\u00e8le de Kirchhoff.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-paragraphe\">Capteur L0\u00b0 en immersion mono-\u00e9l\u00e9ment \u00e0 5,0\u00a0MHz de \u00d86,35\u00a0mm<\/h2>\n<\/p>\n<p><span style=\"line-height: 1.5em;\">Pour le capteur en immersion circulaire de \u00d86,35\u00a0mm \u00e0 5,0\u00a0MHz, l\u2019inspection est r\u00e9alis\u00e9e avec le mode L0\u00b0 pour une hauteur d\u2019eau de 50\u00a0mm. Le signal d\u2019entr\u00e9e a une fr\u00e9quence de 5,0\u00a0MHz, une bande passante de 70% et une phase de 255\u00b0.<\/span><\/p>\n<\/p>\n<p>Le faisceau acoustique est illustr\u00e9 ci-dessous.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align: center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-23.png\" style=\"text-decoration: none;\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"middle\" alt=\"\" class=\"mediabox alignnone wp-image-3918\" height=\"200\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-23-small.png\" width=\"200\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-23-small.png 200w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-23-small-150x150.png 150w\" sizes=\"auto, (max-width: 200px) 100vw, 200px\" \/><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Les r\u00e9sultats sont \u00e9talonn\u00e9s par rapport au TG de \u00d82\u00a0mm \u00e0 8\u00a0mm de profondeur inspect\u00e9 dans un autre bloc en ondes L0\u00b0.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align: center;\"><a class=\"mediabox\" href=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-24.png\" style=\"text-decoration: none;\" title=\"\"><img loading=\"lazy\" decoding=\"async\" align=\"middle\" alt=\"\" class=\"mediabox alignnone wp-image-3920\" height=\"230\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-24-small.png\" width=\"400\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-24-small.png 400w, https:\/\/www.extende.com\/wp-content\/uploads\/CIVA-Validation-UT-TFP1-24-small-300x173.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/a><\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Les \u00e9carts entre simulations et exp\u00e9riences ne d\u00e9passant pas 2\u00a0dB, les r\u00e9sultats de CIVA sont en bon accord avec ceux obtenus exp\u00e9rimentalement.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Continuer vers <a class=\"lien\" href=\"https:\/\/www.extende.com\/fr\/la-simulation-cnd\/documentation\/validation-experimentale-des-modeles-civa\/validation-experimentale-des-modeles-civa-en-ultrasons\/ultrasons-reflecteurs-artificiels\/reflecteurs-trous-a-fond-plat\/ut-reflecteurs-trous-a-fond-plat-influence-dune-desorientation-du-capteur\/\" target=\"_self\">Influence d&rsquo;une d\u00e9sorientation du capteur<\/a><\/p>\n<\/p>\n<p>Retourner au menu <a class=\"lien\" href=\"https:\/\/www.extende.com\/fr\/la-simulation-cnd\/documentation\/validation-experimentale-des-modeles-civa\/validation-experimentale-des-modeles-civa-en-ultrasons\/ultrasons-reflecteurs-artificiels\/reflecteurs-trous-a-fond-plat\/\" target=\"_self\">R\u00e9flecteurs trous \u00e0 fond plat<\/a><\/p>\n<\/p>\n<p>Retourner au menu <a class=\"lien\" href=\"https:\/\/www.extende.com\/fr\/la-simulation-cnd\/documentation\/validation-experimentale-des-modeles-civa\/validation-experimentale-des-modeles-civa-en-ultrasons\/ultrasons-reflecteurs-artificiels\/\" target=\"_self\">R\u00e9flecteurs artificiels<\/a><\/p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Validation exp\u00e9rimentale et caract\u00e9risation des mod\u00e8les Ultrasons de CIVA, r\u00e9flecteurs artificiels, trous \u00e0 fond plat, logiciel de simulation CND<\/p>\n","protected":false},"author":0,"featured_media":0,"parent":2936,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"templates\/page--extende.html.php","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-3922","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.extende.com\/fr\/wp-json\/wp\/v2\/pages\/3922","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.extende.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.extende.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"replies":[{"embeddable":true,"href":"https:\/\/www.extende.com\/fr\/wp-json\/wp\/v2\/comments?post=3922"}],"version-history":[{"count":1,"href":"https:\/\/www.extende.com\/fr\/wp-json\/wp\/v2\/pages\/3922\/revisions"}],"predecessor-version":[{"id":5612,"href":"https:\/\/www.extende.com\/fr\/wp-json\/wp\/v2\/pages\/3922\/revisions\/5612"}],"up":[{"embeddable":true,"href":"https:\/\/www.extende.com\/fr\/wp-json\/wp\/v2\/pages\/2936"}],"wp:attachment":[{"href":"https:\/\/www.extende.com\/fr\/wp-json\/wp\/v2\/media?parent=3922"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}