{"id":4566,"date":"2025-06-24T18:39:13","date_gmt":"2025-06-24T16:39:13","guid":{"rendered":""},"modified":"2025-06-24T18:52:10","modified_gmt":"2025-06-24T16:52:10","slug":"inclusion-dans-leau-monoelement-capteur-2-25-mhz","status":"publish","type":"page","link":"https:\/\/www.extende.com\/fr\/la-simulation-cnd\/documentation\/validation-experimentale-des-modeles-civa\/validation-experimentale-des-modeles-civa-en-ultrasons\/caracterisation-du-champ-de-capteurs-dans-leau-par-mesure-des-echos-dinclusion-solides-et-dun-plan-infini\/capteurs-mono-element\/inclusion-dans-leau-monoelement-capteur-2-25-mhz\/","title":{"rendered":"Inclusion dans l&rsquo;eau &#8211; monoelement &#8211; Capteur 2.25 MHz"},"content":{"rendered":"<h2 class=\"titre-accordeon\">Param\u00e8tres d&rsquo;entr\u00e9e dans CIVA<\/h2>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-paragraphe\">Param\u00e8tres du capteur<\/h2>\n<\/p>\n<p>Le diam\u00e8tre du capteur entr\u00e9 dans CIVA est celui donn\u00e9 par le fabricant\u00a0:<\/p>\n<\/p>\n<ul class=\"liste-carres-noirs\" style=\"margin-left: 40px;\">\n<li><strong>Diam\u00e8tre du capteur\u00a0: 6.35mm<\/strong><\/li>\n<\/ul>\n<p>La fr\u00e9quence centrale du signal d\u2019entr\u00e9e est la fr\u00e9quence nominale donn\u00e9e par le fabricant :<\/p>\n<\/p>\n<ul class=\"liste-carres-noirs\" style=\"margin-left: 40px;\">\n<li><strong>Fr\u00e9quence centrale = 2.25 MHz<\/strong><\/li>\n<\/ul>\n<p>Les deux autres param\u00e8tres du signal d\u2019entr\u00e9e, la bande passante et la phase, sont d\u00e9termin\u00e9s par ajustement des formes temporelles des \u00e9chos mesur\u00e9s et simul\u00e9s d\u2019un r\u00e9flecteur de r\u00e9f\u00e9rence pour lequel les pr\u00e9dictions de CIVA ont \u00e9t\u00e9 valid\u00e9es. Le r\u00e9flecteur de r\u00e9f\u00e9rence choisi pour ce capteur est un trou g\u00e9n\u00e9ratrice (TG) de diam\u00e8tre \u00d8=2mm plac\u00e9 \u00e0 44mm de profondeur dans le bloc d\u2019\u00e9talonnage en acier. Cet \u00e9cho de r\u00e9f\u00e9rence a \u00e9t\u00e9 mesur\u00e9 pour une hauteur d\u2019eau de 20mm.<\/p>\n<\/p>\n<p>La bande passante et la phase du signal d\u2019entr\u00e9e ainsi d\u00e9termin\u00e9es sont\u00a0(Figure 14):<\/p>\n<\/p>\n<ul class=\"liste-carres-noirs\" style=\"margin-left: 40px;\">\n<li><strong>Bande passante =55%<\/strong><\/li>\n<li><strong>Phase = 40\u00b0<\/strong><\/li>\n<\/ul>\n<p style=\"text-align:center;\"><img loading=\"lazy\" decoding=\"async\" width=\"358\" height=\"125\" alt=\"\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_14_new.png\" class=\"alignnone wp-image-4544\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_14_new.png 358w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_14_new-300x105.png 300w\" sizes=\"auto, (max-width: 358px) 100vw, 358px\" \/><\/p>\n<\/p>\n<p class=\"wp-caption-text\">Figure 14 : Superposition apr\u00e8s ajustement de la bande passante et de la phase du signal d\u2019entr\u00e9e CIVA des A-scans mesur\u00e9, simul\u00e9 avec SOV_COMPLET de l\u2019\u00e9cho d\u2019un TG \u00d82mm plac\u00e9 \u00e0 44mm de profondeur dans un bloc d\u2019\u00e9talonnage en acier, hauteur d\u2019eau 20mm. Amplitudes normalis\u00e9es. Capteur plan \u00d86.35mm, 2.25MHz.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-paragraphe\">Param\u00e8tres des inclusions<\/h2>\n<\/p>\n<p>Les diam\u00e8tres des inclusions entr\u00e9s dans CIVA sont ceux donn\u00e9s par le fabricant\u00a0:<\/p>\n<\/p>\n<ul class=\"liste-carres-noirs\" style=\"margin-left: 40px;\">\n<li><strong>Diam\u00e8tre des inclusions = 1, 2, 4 et 6 mm<\/strong><\/li>\n<\/ul>\n<p>Les vitesses des ondes L et T dans les inclusions en acier inoxydable\u00a0n\u2019ont pas pu \u00eatre mesur\u00e9es pr\u00e9cis\u00e9ment. Elles ont cependant \u00e9t\u00e9 d\u00e9termin\u00e9es gr\u00e2ce \u00e0 une rapide \u00e9tude param\u00e9trique avec CIVA\u00a0 utilisant le fait\u00a0:<\/p>\n<\/p>\n<ul class=\"liste-carres-noirs\" style=\"margin-left: 40px;\">\n<li>qu\u2019une variation de la vitesse des ondes T autour de 3000m\/s (vitesse dans un acier) a un effet sur la position et l\u2019amplitude des \u00e9chos arrivant apr\u00e8s l\u2019\u00e9cho sp\u00e9culaire (Figure 15 en haut).<\/li>\n<li>qu\u2019une variation de la vitesse des ondes L a un tr\u00e8s faible effet sur les amplitudes de ces \u00e9chos et pas sur leurs positions (Figure 15 en bas).<\/li>\n<li>que l&rsquo;amplitude de l\u2019\u00e9cho sp\u00e9culaire ne d\u00e9pend pas des valeurs de ces vitesses (Figure 15 haut et bas).<\/li>\n<\/ul>\n<p style=\"text-align:center;\"><img loading=\"lazy\" decoding=\"async\" width=\"487\" height=\"253\" alt=\"\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_15-2.png\" class=\"alignnone wp-image-4545\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_15-2.png 487w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_15-2-300x156.png 300w\" sizes=\"auto, (max-width: 487px) 100vw, 487px\" \/><\/p>\n<\/p>\n<p class=\"wp-caption-text\">Figure 15 : R\u00e9sultats de simulation illustrant l\u2019effet d\u2019une variation de la vitesse des ondes T dans l\u2019inclusion (en haut) et de celle des ondes L (en bas) sur l\u2019\u00e9cho de l\u2019inclusion de \u00d82mm plac\u00e9e dans l\u2019eau \u00e0 60mm du capteur. L\u2019effet de la variation des ondes T sur les \u00e9chos suivant l\u2019\u00e9cho sp\u00e9culaire a \u00e9t\u00e9 utilis\u00e9 pour d\u00e9terminer la vitesse de ces ondes. Capteur plan \u00d86.35mm, 2.25MHz.<\/p>\n<\/p>\n<p>Ainsi, la vitesse des ondes T dans l\u2019inclusion est d\u00e9termin\u00e9e par ajustement des positions temporelles des \u00e9chos arrivant apr\u00e8s le premier \u00e9cho sp\u00e9culaire exp\u00e9rimental\u00a0et simul\u00e9 avec\u00a0SOV-COMPLET (Figure 16 en haut).<\/p>\n<\/p>\n<p>La valeur obtenue est\u00a0:<\/p>\n<\/p>\n<ul class=\"liste-carres-noirs\" style=\"margin-left: 40px;\">\n<li><strong>v<em><sub>T<\/sub><\/em><\/strong><sub>&#8211;<\/sub><strong><sub>acier<\/sub> = 3300 m\/s\u00a0<\/strong>(Figure 16 en bas).<\/li>\n<\/ul>\n<p style=\"text-align:center;\"><img loading=\"lazy\" decoding=\"async\" width=\"576\" height=\"313\" alt=\"\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_16-2.png\" class=\"alignnone wp-image-4546\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_16-2.png 576w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_16-2-300x163.png 300w\" sizes=\"auto, (max-width: 576px) 100vw, 576px\" \/><\/p>\n<\/p>\n<p class=\"wp-caption-text\">Figure 16 : Superposition des A-scans mesur\u00e9s et simul\u00e9s avec SOV-COMPLET apparetenant \u00e0\u00a0l\u2019\u00e9cho de l\u2019inclusion de \u00d82mm plac\u00e9e \u00e0 60mm du capteur\u00a0.\u00a0En haut :\u00a0A-scan mesur\u00e9 et 3 A-scans simul\u00e9s obtenus pour 3 vitesses diff\u00e9rentes des ondes T dans l\u2019inclusion. En bas: A-scans mesur\u00e9 et simul\u00e9 avec la vitesse des ondes T pour laquelle on obtient le meilleur accord. Capteur plan \u00d86.35mm, 2.25MHz.<\/p>\n<\/p>\n<p>Remarque : les mod\u00e8les SOV et SOV-COMPLET simulent les m\u00eames \u00e9chos apr\u00e8s ajustement (Figure 17).\u00a0La vitesse d\u00e9termin\u00e9e ne d\u00e9pend pas du mod\u00e8le choisi pour les simulations<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><img loading=\"lazy\" decoding=\"async\" width=\"465\" height=\"137\" alt=\"\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_17-2.png\" class=\"alignnone wp-image-4547\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_17-2.png 465w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_17-2-300x88.png 300w\" sizes=\"auto, (max-width: 465px) 100vw, 465px\" \/><\/p>\n<\/p>\n<p class=\"wp-caption-text\">Figure 17 : Superposition des A-scans simul\u00e9s avec SOV et SOV-COMPLET de l\u2019\u00e9cho de l\u2019inclusion de \u00d82mm plac\u00e9e \u00e0 60mm du capteur. On voit que\u00a0l\u2019\u00e9cho sp\u00e9culaire et les \u00e9chos suivants ne d\u00e9pendent pas du mod\u00e8le \u00e0 cette distance. Capteur plan \u00d86.35mm, 2.25MHz.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Ensuite, la vitesse des ondes L dans l\u2019inclusion a \u00e9t\u00e9 d\u00e9termin\u00e9e par ajustement des amplitudes des \u00e9chos mesur\u00e9s et simul\u00e9s de l\u2019inclusion de r\u00e9f\u00e9rence arrivant apr\u00e8s le premier \u00e9cho sp\u00e9culaire (Figure 18 en haut).<\/p>\n<\/p>\n<p>La valeur obtenue est\u00a0(Figure 18 en bas):<\/p>\n<\/p>\n<ul class=\"liste-carres-noirs\" style=\"margin-left: 40px;\">\n<li><strong>v<em><sub>L<\/sub><\/em><\/strong><sub>&#8211;<\/sub><strong><sub>acier<\/sub> = 5850 m\/s.<\/strong><\/li>\n<\/ul>\n<p style=\"text-align:center;\"><img loading=\"lazy\" decoding=\"async\" width=\"558\" height=\"314\" alt=\"\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_18-2.png\" class=\"alignnone wp-image-4548\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_18-2.png 558w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_18-2-300x169.png 300w\" sizes=\"auto, (max-width: 558px) 100vw, 558px\" \/><\/p>\n<\/p>\n<p class=\"wp-caption-text\">Figure 18 : Superposition des A-scans mesur\u00e9 et simul\u00e9 avec SOV-COMPLET de l\u2019\u00e9cho de l\u2019inclusion de \u00d82mm plac\u00e9e \u00e0 60mm du capteur. En haut :\u00a0A-scans simul\u00e9s obtenus pour 3 vitesses diff\u00e9rentes des ondes L dans l\u2019inclusion. En bas :\u00a0A-scan simul\u00e9 obtenu avec la vitesse des ondes L pour laquelle les A-scans pr\u00e9sentent\u00a0le meilleur accord. Amplitudes normalis\u00e9es. Capteur plan \u00d86.35mm, 2.25MHz.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Ces vitesses des ondes L et T d\u00e9termin\u00e9es pour l\u2019inclusion de \u00d82mm ont \u00e9t\u00e9 utilis\u00e9es en entr\u00e9e de CIVA pour les autres inclusions en supposant qu\u2019elles sont identiques.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-paragraphe\">Param\u00e8tres de l&rsquo;eau<\/h2>\n<\/p>\n<p>Cette vitesse a \u00e9t\u00e9 mesur\u00e9e en utilisant les rebonds successifs d\u2019un \u00e9cho de surface sur un plan infini.<\/p>\n<\/p>\n<ul class=\"liste-carres-noirs\" style=\"margin-left: 40px;\">\n<li><strong>vL<\/strong><strong><sub>eau<\/sub> = 1483 m\/s<\/strong><\/li>\n<\/ul>\n<p>L\u2019att\u00e9nuation dans l\u2019eau a \u00e9t\u00e9 n\u00e9glig\u00e9e pour les simulations \u00e0 la fr\u00e9quence de 2.25MHz car elle est tr\u00e8s faible. Par ailleurs, nous avons\u00a0v\u00e9rifi\u00e9 en comparant des simulations r\u00e9alis\u00e9es avec et sans att\u00e9nuation dans l\u2019eau qu\u2019elle est n&rsquo;a pas d&rsquo;effet pour les\u00a0distances capteur\/r\u00e9flecteur choisis dans\u00a0cette \u00e9tude.<\/p>\n<\/p>\n<ul class=\"liste-carres-noirs\" style=\"margin-left: 40px;\">\n<li><strong>Att\u00e9nuation dans l\u2019eau n\u00e9glig\u00e9e pour le capteur \u00e0 2,25MHz<\/strong><\/li>\n<\/ul>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-accordeon\">R\u00e9f\u00e9rence pour les amplitudes lors des comparaisons mesure\/CIVA<\/h2>\n<\/p>\n<p>L&rsquo;amplitude de r\u00e9f\u00e9rence pour les compraisons exp\u00e9rience\/simulation est l\u2019amplitude de l\u2019\u00e9cho sp\u00e9culaire L0\u00b0 du TG\u00d82mm situ\u00e9 \u00e0 44mm dans le bloc d\u2019\u00e9talonnage inspect\u00e9 avec une hauteur d\u2019eau de 20mm (Figure 14). Les amplitudes de cet \u00e9cho obtenues avec les mod\u00e8les SOV et SOV_COMPLET \u00e9tant quasi identiques, la m\u00eame valeur en points a \u00e9t\u00e9 utilis\u00e9e comme r\u00e9f\u00e9rence pour les amplitudes pour les 2 mod\u00e8les (Figure 19).<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><img loading=\"lazy\" decoding=\"async\" width=\"442\" height=\"168\" alt=\"\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_19-2.png\" class=\"alignnone wp-image-4549\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_19-2.png 442w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_19-2-300x114.png 300w\" sizes=\"auto, (max-width: 442px) 100vw, 442px\" \/><\/p>\n<\/p>\n<p class=\"wp-caption-text\">Figure 19 : Superposition des A-scans simul\u00e9s avec SOV et SOV_COMPLET de l\u2019\u00e9cho du TG de r\u00e9f\u00e9rence pour les amplitudes (plac\u00e9 \u00e0 44mm de profondeur dans un bloc d\u2019\u00e9talonnage en acier, hauteur d\u2019eau 20mm) montrant que les deux mod\u00e8les pr\u00e9disent des \u00e9chos tr\u00e8s proches. Amplitudes comparables. Capteur plan \u00d86.35mm, 2.25MHz.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-accordeon\">Champ du capteur plan 2,25 MHz dans l&rsquo;eau<\/h2>\n<\/p>\n<p>Les Figure 20 et Figure 21 ci-dessous montrent le champ simul\u00e9 \u00e9mis par le capteur dans l\u2019eau.<\/p>\n<\/p>\n<p>L\u2019amplitude maximale \u00e9mise par le capteur sur son axe est \u00e0 15.5mm de distance. La largeur de la tache focale \u00e0 -3dB est de 1.9mm \u00e0 cette distance et augmente de part et autre (Figure 20).<\/p>\n<\/p>\n<p>Les billes de \u00d84 et 6 mm sont donc beaucoup plus grandes que la tache focale comme on peut le constater sur la Figure 21\u00a0o\u00f9 les inclusions sont repr\u00e9sent\u00e9es avec une \u00e9chelle identique \u00e0 celle de\u00a0la cartographie du champ afin de donner une id\u00e9e de leurs dimensions par rapport \u00e0 la tache focale.<\/p>\n<\/p>\n<p style=\"text-align:center;\"><img loading=\"lazy\" decoding=\"async\" width=\"627\" height=\"289\" alt=\"\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_20-2.png\" class=\"alignnone wp-image-4550\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_20-2.png 627w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_20-2-300x138.png 300w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_20-2-600x277.png 600w\" sizes=\"auto, (max-width: 627px) 100vw, 627px\" \/><\/p>\n<\/p>\n<p class=\"wp-caption-text\">Figure 20 : Simulation avec CIVA du champ \u00e9mis par le capteur dans l\u2019eau. En haut profil du champ le long de l\u2019axe du capteur montrant un maximum \u00e0 15.5mm de distance du capteur. En bas, cartographies (6mmx6mm) du champ dans des plans perpendiculaires \u00e0 son axe \u00e0 diff\u00e9rentes distances du capteur. Amplitudes comparables (r\u00e9f = amplitude maximale du champ obtenue \u00e0 D=15.5mm). Capteur plan \u00d86.35mm, 2.25MHz.<\/p>\n<p>\u00a0<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><img loading=\"lazy\" decoding=\"async\" width=\"627\" height=\"235\" alt=\"\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_21-1.png\" class=\"alignnone wp-image-4551\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_21-1.png 627w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_21-1-300x112.png 300w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_21-1-600x225.png 600w\" sizes=\"auto, (max-width: 627px) 100vw, 627px\" \/><\/p>\n<\/p>\n<p class=\"wp-caption-text\">Figure 21 : Simulation avec CIVA du champ \u00e9mis par le capteur dans l\u2019eau. Repr\u00e9sentation des inclusions \u00e0 la m\u00eame \u00e9chelle que celle de la cartographie du champ afin de donner une id\u00e9e des dimensions relatives des inclusions et du faisceau. Capteur plan \u00d86.35mm, 2.25MHz.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-accordeon\">R\u00e9sultats obtenus pour les inclusions en acier<\/h2>\n<\/p>\n<p>On rappelle dans le tableau ci-dessous les bridages de CIVA dans le cas du capteur \u00e0 2.25MHz. Ces bridages ont \u00e9t\u00e9 temporairement supprim\u00e9s dans une version de d\u00e9veloppement afin de permettre le calcul des \u00e9chos des quatre inclusions avec les 3 mod\u00e8les SOV, SOV_COMPLET et SPECULAIRE et ainsi \u00e9valuer la pertinence des bridages propos\u00e9s. Cela signnifie que dans la version commerciale, le calcul des configurations correspondant aux cases \u00ab\u00a0non\u00a0\u00bb du tableau 2 n&rsquo;est pas possible.<\/p>\n<\/p>\n<table align=\"center\" border=\"1\" cellpadding=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td style=\"width:125px;\">\n<p style=\"text-align:center;\"><strong>2.25MHZ<\/strong><\/p>\n<\/td>\n<td style=\"width:133px;\">\n<p style=\"text-align:center;\">Inclusion \u00d8 1mm<\/p>\n<\/td>\n<td style=\"width:133px;\">\n<p style=\"text-align:center;\">Inclusion \u00d8 2mm<\/p>\n<\/td>\n<td style=\"width:133px;\">\n<p style=\"text-align:center;\">Inclusion \u00d8 4mm<\/p>\n<\/td>\n<td style=\"width:133px;\">\n<p style=\"text-align:center;\">Inclusion \u00d8 6mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width:125px;\">\n<p style=\"text-align:center;\">SOV<\/p>\n<\/td>\n<td style=\"width:133px;\">\n<p style=\"text-align:center;\">oui<\/p>\n<\/td>\n<td style=\"width:133px;\">\n<p style=\"text-align:center;\">oui<\/p>\n<\/td>\n<td style=\"width:133px;\">\n<p style=\"text-align:center;\">oui<\/p>\n<\/td>\n<td style=\"width:133px;\">\n<p style=\"text-align:center;\">non<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width:125px;\">\n<p style=\"text-align:center;\">SOV_COMPLET<\/p>\n<\/td>\n<td style=\"width:133px;\">\n<p style=\"text-align:center;\">oui<\/p>\n<\/td>\n<td style=\"width:133px;\">\n<p style=\"text-align:center;\">oui<\/p>\n<\/td>\n<td style=\"width:133px;\">\n<p style=\"text-align:center;\">oui<\/p>\n<\/td>\n<td style=\"width:133px;\">\n<p style=\"text-align:center;\">non<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width:125px;\">\n<p style=\"text-align:center;\">SPECULAIRE<\/p>\n<\/td>\n<td style=\"width:133px;\">\n<p style=\"text-align:center;\">non<\/p>\n<\/td>\n<td style=\"width:133px;\">\n<p style=\"text-align:center;\">non<\/p>\n<\/td>\n<td style=\"width:133px;\">\n<p style=\"text-align:center;\">non<\/p>\n<\/td>\n<td style=\"width:133px;\">\n<p style=\"text-align:center;\">oui<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"wp-caption-text\">Tableau 2 : Mod\u00e8les disponibles dans CIVA pour le calcul des \u00e9chos des inclusions en fonction de leur diam\u00e8tre pour le capteur \u00e0 2.25MHz.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-paragraphe\">R\u00e9sultats exp\u00e9rimentaux<\/h2>\n<\/p>\n<p>Les courbes \u00e9chodynamiques amplitude\/distance exp\u00e9rimentales sont pr\u00e9sent\u00e9es sur la Figure 22.\u00a0En haut, les amplitudes sont relatives \u00e0 celles de l\u2019\u00e9cho de r\u00e9f\u00e9rence;\u00a0en bas les amplitudes sont normalis\u00e9es. On peut noter que :<\/p>\n<\/p>\n<ul class=\"liste-carres-noirs\" style=\"margin-left: 40px;\">\n<li>l\u2019amplitude maximum des \u00e9chos augmente avec le diam\u00e8tre de l\u2019inclusion. L&rsquo;amplitude augmente\u00a0de 5 \u00e0 6 dB quand le diam\u00e8tre de l\u2019inclusion est doubl\u00e9. On note \u00e9galement une augmentation de 3.5dB entre les inclusions de 4 mm et 6mm.<\/li>\n<li>la distance \u00ab\u00a0d<sub>max\u00a0<\/sub>\u00bb \u00e0 laquelle l\u2019amplitude de l\u2019\u00e9cho est maximale ne d\u00e9pend quasiment pas du diam\u00e8tre de l\u2019inclusion\u00a0: d<sub>max\u00a0<\/sub> = 14 ou 14.5mm.<\/li>\n<li>au-del\u00e0 de \u00ab\u00a0d<sub>max\u00a0<\/sub>\u00bb, la pente de la d\u00e9croissance ne d\u00e9pend pas du diam\u00e8tre de l\u2019inclusion.<\/li>\n<\/ul>\n<p style=\"text-align:center;\"><img loading=\"lazy\" decoding=\"async\" width=\"560\" height=\"574\" alt=\"\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_22-1.png\" class=\"alignnone wp-image-4552\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_22-1.png 560w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_22-1-293x300.png 293w\" sizes=\"auto, (max-width: 560px) 100vw, 560px\" \/><\/p>\n<\/p>\n<p class=\"wp-caption-text\">Figure 22 : R\u00e9sultats exp\u00e9rimentaux montrant l\u2019\u00e9volution des courbes \u00e9chodynamiques amplitude\/distance avec les diam\u00e8tres (de 1mm \u00e0 6mm) des inclusions en acier. En haut) amplitudes comparables, r\u00e9f\u00e9rence: \u00e9cho L0\u00b0 d\u2019un TG\u00d82mm \u00e0 44mm de profondeur dans la cale d\u2019\u00e9talonnage en acier ferritique, hauteur d\u2019eau 20mm. En bas) amplitudes normalis\u00e9es. Capteur plan \u00d86.35mm, 2.25MHz.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Les courbes XY exp\u00e9rimentales obtenues pour les 4 inclusions sont pr\u00e9sent\u00e9es sur la Figure 23 (amplitudes normalis\u00e9es). La largeur de la tache focale ne d\u00e9pend pas du diam\u00e8tre de l\u2019inclusion.<\/p>\n<\/p>\n<p style=\"text-align:center;\"><img loading=\"lazy\" decoding=\"async\" width=\"539\" height=\"274\" alt=\"\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_23-1.png\" class=\"alignnone wp-image-4553\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_23-1.png 539w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_23-1-300x153.png 300w\" sizes=\"auto, (max-width: 539px) 100vw, 539px\" \/><\/p>\n<\/p>\n<p class=\"wp-caption-text\">Figure 23 : R\u00e9sultats exp\u00e9rimentaux montrant l\u2019\u00e9volution des coupes XY exp\u00e9rimentales \u00e0 la distance focale exp\u00e9rimentale avec les diam\u00e8tres (1 \u00e0 6mm) des inclusions en acier. Amplitudes normalis\u00e9es. Capteur plan \u00d86.35mm, 2.25MHz.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>La forme des \u00e9chos sp\u00e9culaires des inclusions situ\u00e9es \u00e0 la distance focale de 14.5mm ou en champ lointain du capteur (60mm) ne d\u00e9pend pas du diam\u00e8tre de l\u2019inclusion (Figure 24). L\u2019\u00e9cho arrivant apr\u00e8s la premi\u00e8re contribution est d\u2019autant plus \u00e9loign\u00e9 en temps du premier \u00e9cho que le diam\u00e8tre de l\u2019inclusion est grand. L\u2019origine des \u00e9chos apparissant apr\u00e8s la contribution sp\u00e9culaire n\u2019est pas pr\u00e9cis\u00e9ment connue, il se produit un m\u00e9lange entre des ondes rasantes et des ondes p\u00e9n\u00e9trant\u00a0l\u2019inclusion dans laquelle elles se propagent, rebondissent avec d\u2019\u00e9ventuelles conversions de modes, interf\u00e8rent\u2026<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><img loading=\"lazy\" decoding=\"async\" width=\"583\" height=\"267\" alt=\"\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_24-1.png\" class=\"alignnone wp-image-4554\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_24-1.png 583w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_24-1-300x137.png 300w\" sizes=\"auto, (max-width: 583px) 100vw, 583px\" \/><\/p>\n<\/p>\n<p class=\"wp-caption-text\">Figure 24 : R\u00e9sultats exp\u00e9rimentaux montrant l\u2019\u00e9volution des A-scans avec les diam\u00e8tres (de 1mm \u00e0 6mm) des inclusions en acier, distance capteur\/inclusion = 14.5mm \u00e0 gauche et 60mm \u00e0 droite. Amplitudes normalis\u00e9es. Capteur plan \u00d86.35mm, 2.25MHz.<\/p>\n<\/p>\n<p class=\"titre-paragraphe\">\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-paragraphe\">Comparaison mesure\/CIVA<\/h2>\n<\/p>\n<ul>\n<li>\n<h3 class=\"titre-paragraphe\">Courbes amplitude\/distance<\/h3>\n<\/li>\n<\/ul>\n<p>Les comparaisons des courbes amplitude\/distance mesur\u00e9es et simul\u00e9es avec les trois mod\u00e8les SOV-COMPLET, SOV et SPECULAIRE sont pr\u00e9sent\u00e9es Figure 25 (inclusions \u00d81mm et 2mm) et Figure 26 (inclusions \u00d84mm et 6mm).<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><img loading=\"lazy\" decoding=\"async\" width=\"578\" height=\"591\" alt=\"\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_25-1.png\" class=\"alignnone wp-image-4555\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_25-1.png 578w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_25-1-293x300.png 293w\" sizes=\"auto, (max-width: 578px) 100vw, 578px\" \/><\/p>\n<\/p>\n<p class=\"wp-caption-text\">Figure 25 : Comparaison des courbes amplitude\/distance mesur\u00e9es et simul\u00e9es avec SOV, SOV-COMPLET et SPECULAIRE, cas des inclusions de 1 et 2mm. R\u00e9f\u00e9rence pour les amplitudes: \u00e9cho L0\u00b0 d\u2019un TG\u00d82mm \u00e0 44mm de profondeur dans une cale d\u2019\u00e9talonnage en acier ferritique, hauteur d\u2019eau 20mm. Dans CIVA non d\u00e9brid\u00e9e les mod\u00e8les SOV et SOV_COMPLET sont autoris\u00e9s pour les inclusions de 1 et 2mm. Capteur plan \u00d86.35mm, 2.25MHz.<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><img loading=\"lazy\" decoding=\"async\" width=\"598\" height=\"600\" alt=\"\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_26-1.png\" class=\"alignnone wp-image-4556\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_26-1.png 598w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_26-1-300x300.png 300w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_26-1-150x150.png 150w\" sizes=\"auto, (max-width: 598px) 100vw, 598px\" \/><\/p>\n<\/p>\n<p class=\"wp-caption-text\">Figure 26 : Comparaison des courbes amplitude\/distance mesur\u00e9es et simul\u00e9es avec SOV, SOV-COMPLET et SPECULAIRE, cas des inclusions de 4 et 6mm. R\u00e9f\u00e9rence pour les amplitudes: \u00e9cho L0\u00b0 d\u2019un TG\u00d82mm \u00e0 44mm de profondeur dans une cale d\u2019\u00e9talonnage en acier ferritique, hauteur d\u2019eau 20mm. Dans CIVA non d\u00e9brid\u00e9e les mod\u00e8les SOV et SOV_COMPLET sont autoris\u00e9s pour l\u2019inclusion de 4mm et le mod\u00e8le SPECULAIRE est autoris\u00e9 pour l\u2019inclusion de 6mm. Capteur plan \u00d86.35mm, 2.25MHz<\/p>\n<\/p>\n<p>La distance d<sub>max\u00a0<\/sub>\u00e0 laquelle l\u2019amplitude de la courbe amplitude\/distance est maximale est indiqu\u00e9e dans le Tableau 3. Les \u00e9carts entre d<sub>maxEXPERIMENTAL et\u00a0<\/sub>d<sub>maxCIVA\u00a0<\/sub>sont indiqu\u00e9s dans le Tableau 4.<\/p>\n<\/p>\n<table align=\"center\" border=\"1\" cellpadding=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td style=\"width:171px;\">\n<p style=\"text-align:center;\"><strong>Distance \u201cD\u201d amp max (mm) -\/+0.5mm<\/strong><\/p>\n<\/td>\n<td style=\"width:83px;\">\n<p style=\"text-align:center;\"><strong>Champ Simul\u00e9<\/strong><\/p>\n<\/td>\n<td style=\"width:106px;\">\n<p style=\"text-align:center;\"><strong>Inclusion <\/strong><strong>\u00d8<\/strong><strong>1mm<\/strong><\/p>\n<\/td>\n<td style=\"width:106px;\">\n<p style=\"text-align:center;\"><strong>Inclusion <\/strong><strong>\u00d8<\/strong><strong>2mm<\/strong><\/p>\n<\/td>\n<td style=\"width:106px;\">\n<p style=\"text-align:center;\"><strong>Inclusion <\/strong><strong>\u00d8<\/strong><strong>4mm<\/strong><\/p>\n<\/td>\n<td style=\"width:106px;\">\n<p style=\"text-align:center;\"><strong>Inclusion <\/strong><strong>\u00d8<\/strong><strong>6mm<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width:171px;\">\n<p style=\"text-align:center;\">\u00a0<\/p>\n<\/td>\n<td style=\"width:83px;\">\n<p style=\"text-align:center;\">15.5<\/p>\n<\/td>\n<td style=\"width:106px;\">\n<p style=\"text-align:center;\">\u00a0<\/p>\n<\/td>\n<td style=\"width:106px;\">\n<p style=\"text-align:center;\">\u00a0<\/p>\n<\/td>\n<td style=\"width:106px;\">\n<p style=\"text-align:center;\">\u00a0<\/p>\n<\/td>\n<td style=\"width:106px;\">\n<p style=\"text-align:center;\">\u00a0<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width:171px;\">\n<p style=\"text-align:center;\"><strong>Mesure<\/strong><\/p>\n<\/td>\n<td style=\"width:83px;\">\n<p style=\"text-align:center;\">\u00a0<\/p>\n<\/td>\n<td style=\"width:106px;\">\n<p style=\"text-align:center;\">14<\/p>\n<\/td>\n<td style=\"width:106px;\">\n<p style=\"text-align:center;\">14.5<\/p>\n<\/td>\n<td style=\"width:106px;\">\n<p style=\"text-align:center;\">14<\/p>\n<\/td>\n<td style=\"width:106px;\">\n<p style=\"text-align:center;\">14<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width:171px;\">\n<p style=\"text-align:center;\"><strong>SOV<\/strong><\/p>\n<\/td>\n<td style=\"width:83px;\">\n<p style=\"text-align:center;\">\u00a0<\/p>\n<\/td>\n<td style=\"width:106px;\">\n<p style=\"text-align:center;\"><strong>15<\/strong><\/p>\n<\/td>\n<td style=\"width:106px;\">\n<p style=\"text-align:center;\"><strong>14.5<\/strong><\/p>\n<\/td>\n<td style=\"width:106px;\">\n<p style=\"text-align:center;\"><strong>13.5<\/strong><\/p>\n<\/td>\n<td style=\"width:106px;\">\n<p style=\"text-align:center;\">13<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width:171px;\">\n<p style=\"text-align:center;\"><strong>SOV_COMPLET<\/strong><\/p>\n<\/td>\n<td style=\"width:83px;\">\n<p style=\"text-align:center;\">\u00a0<\/p>\n<\/td>\n<td style=\"width:106px;\">\n<p style=\"text-align:center;\"><strong>13.5<\/strong><\/p>\n<\/td>\n<td style=\"width:106px;\">\n<p style=\"text-align:center;\"><strong>14<\/strong><\/p>\n<\/td>\n<td style=\"width:106px;\">\n<p style=\"text-align:center;\"><strong>13.5<\/strong><\/p>\n<\/td>\n<td style=\"width:106px;\">\n<p style=\"text-align:center;\">13.5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width:171px;\">\n<p style=\"text-align:center;\"><strong>SPECULAIRE<\/strong><\/p>\n<\/td>\n<td style=\"width:83px;\">\n<p style=\"text-align:center;\">\u00a0<\/p>\n<\/td>\n<td style=\"width:106px;\">\n<p style=\"text-align:center;\">14<\/p>\n<\/td>\n<td style=\"width:106px;\">\n<p style=\"text-align:center;\">14<\/p>\n<\/td>\n<td style=\"width:106px;\">\n<p style=\"text-align:center;\">13<\/p>\n<\/td>\n<td style=\"width:106px;\">\n<p style=\"text-align:center;\"><strong>14<\/strong><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"wp-caption-text\">Tableau 3 : Distances capteur\/inclusion correspondant au maximum d\u2019amplitude du champ \u00e9mis sur l\u2019axe du capteur ou aux distances auxquelles l\u2019amplitude de la courbe amplitude\/distance est maximale. R\u00e9sultats de mesure et de simulations avec les 3 mod\u00e8les. Les nombres en caract\u00e8res gras correspondent aux cas non brid\u00e9s dans CIVA. Capteur plan \u00d86.35mm, 2.25MHz.<\/p>\n<p>\u00a0<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<table align=\"center\" border=\"1\" cellpadding=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td style=\"width:171px;\">\n<p style=\"text-align:center;\"><strong>\u0394<\/strong><strong>D<sub>sim\/exp<\/sub> amp max (mm)<\/strong><\/p>\n<\/td>\n<td style=\"width:126px;\">\n<p style=\"text-align:center;\"><strong>Inclusion <\/strong><strong>\u00d8<\/strong><strong>1mm<\/strong><\/p>\n<\/td>\n<td style=\"width:126px;\">\n<p style=\"text-align:center;\"><strong>Inclusion <\/strong><strong>\u00d8<\/strong><strong>2mm<\/strong><\/p>\n<\/td>\n<td style=\"width:126px;\">\n<p style=\"text-align:center;\"><strong>Inclusion <\/strong><strong>\u00d8<\/strong><strong>4mm<\/strong><\/p>\n<\/td>\n<td style=\"width:126px;\">\n<p style=\"text-align:center;\"><strong>Inclusion <\/strong><strong>\u00d8<\/strong><strong>6mm<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width:171px;\">\n<p style=\"text-align:center;\"><strong>SOV<\/strong><\/p>\n<\/td>\n<td style=\"width:126px;\">\n<p style=\"text-align:center;\"><strong>1<\/strong><\/p>\n<\/td>\n<td style=\"width:126px;\">\n<p style=\"text-align:center;\"><strong>0<\/strong><\/p>\n<\/td>\n<td style=\"width:126px;\">\n<p style=\"text-align:center;\"><strong>-0.5<\/strong><\/p>\n<\/td>\n<td style=\"width:126px;\">\n<p style=\"text-align:center;\">-1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width:171px;\">\n<p style=\"text-align:center;\"><strong>SOV_COMPLET<\/strong><\/p>\n<\/td>\n<td style=\"width:126px;\">\n<p style=\"text-align:center;\"><strong>-0.5<\/strong><\/p>\n<\/td>\n<td style=\"width:126px;\">\n<p style=\"text-align:center;\"><strong>-0.5<\/strong><\/p>\n<\/td>\n<td style=\"width:126px;\">\n<p style=\"text-align:center;\"><strong>-0.5<\/strong><\/p>\n<\/td>\n<td style=\"width:126px;\">\n<p style=\"text-align:center;\">-0.5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width:171px;\">\n<p style=\"text-align:center;\"><strong>SPECULAIRE<\/strong><\/p>\n<\/td>\n<td style=\"width:126px;\">\n<p style=\"text-align:center;\">0<\/p>\n<\/td>\n<td style=\"width:126px;\">\n<p style=\"text-align:center;\">-0.5<\/p>\n<\/td>\n<td style=\"width:126px;\">\n<p style=\"text-align:center;\">-1<\/p>\n<\/td>\n<td style=\"width:126px;\">\n<p style=\"text-align:center;\"><strong>0<\/strong><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"wp-caption-text\">Tableau 4 : Ecarts entre mesure\/CIVA entre les distances capteur\/inclusion du tableau pr\u00e9c\u00e9dent. Les nombres en caract\u00e8res gras correspondent aux cas non brid\u00e9s dans CIVA. Capteur plan \u00d86.35mm, 5MHz.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p><strong>Mod\u00e8les SOV-COMPLET et SPECULAIRE<\/strong>\u00a0: un tr\u00e8s bon accord est obtenu avec l&rsquo;exp\u00e9rience pour les 4 inclusions \u00e0 toutes les distances. Les \u00e9carts ne d\u00e9passent pas 2dB sauf aux tr\u00e8s petites distances. Les positions de \u00ab\u00a0d<sub>max<\/sub>\u00a0\u00bb sont bien pr\u00e9dites pour les 4 inclusions.<\/p>\n<\/p>\n<p>Plus en d\u00e9tail\u00a0:<\/p>\n<\/p>\n<ul class=\"liste-carres-noirs\" style=\"margin-left: 40px;\">\n<li>En champ lointain les \u00e9carts mesure\/simulation sont &lt; 1dB pour toutes les inclusions sauf dans le cas de l\u2019inclusion de 6mm et du mod\u00e8le SOV_COMPLET\u00a0pour lequel l\u2019\u00e9cart mesure\/simulation atteint un peu plus de 2dB alors que SPECULAIRE est plus proche de la mesure. Cet \u00e9cart sup\u00e9rieur \u00e0 2dB peut \u00eatre attribu\u00e9 \u00e0 une limite du mod\u00e8le concernant le calcul des coefficients de diffraction pour les grands \u00ab\u00a0ka\u00a0\u00bb (cf <a class=\"lien\" href=\"https:\/\/www.extende.com\/fr\/la-simulation-cnd\/documentation\/validation-experimentale-des-modeles-civa\/validation-experimentale-des-modeles-civa-en-ultrasons\/caracterisation-du-champ-de-capteurs-dans-leau-par-mesure-des-echos-dinclusion-solides-et-dun-plan-infini\/informations-sur-les-modeles-speculaire-sov-et-sov-complet\/\" target=\"_blank\" title=\"(Nouvelle fen\u00eatre)\">here<\/a>).<\/li>\n<\/ul>\n<ul class=\"liste-carres-noirs\" style=\"margin-left: 40px;\">\n<li>Autour de \u00ab\u00a0d<sub>max\u00a0<\/sub>\u00bb les courbes amplitude\/distance pr\u00e9dites par SOV_COMPLET et SPECULAIRE sont en tr\u00e8s bon accord avec la mesure (\u00e9carts inf\u00e9rieurs \u00e0 2dB).<\/li>\n<li>Les \u00e9carts sont plus importants aux tr\u00e8s petites distances mais ne d\u00e9passent pas 4 dB.<\/li>\n<li>La distance \u00ab\u00a0d<sub>max\u00a0<\/sub>\u00bb ne d\u00e9pend quasiment pas du diam\u00e8tre de l\u2019inclusion selon SOV_COMPLET et SPECULAIRE (Tableau 3) comme c\u2019est le cas exp\u00e9rimentalement. Les deux mod\u00e8les ont tendance \u00e0 l\u00e9g\u00e8rement sous-estimer \u00ab\u00a0d<sub>max\u00a0<\/sub>\u00bb par rapport \u00e0 la mesure, mais les \u00e9carts entre les valeurs mesur\u00e9e et simul\u00e9e restent inf\u00e9rieurs \u00e0 1mm (Tableau 4)<\/li>\n<\/ul>\n<p><strong>Mod\u00e8le SOV<\/strong>: l\u2019accord avec la mesure est moins bon que pour les 2pr\u00e9c\u00e9dents mod\u00e8les lorsque les inclusions sont pr\u00e8s du capteur.<\/p>\n<\/p>\n<p>Plus en d\u00e9tail\u00a0:<\/p>\n<\/p>\n<ul class=\"liste-carres-noirs\" style=\"margin-left: 40px;\">\n<li>En champ lointain les \u00e9carts mesure\/simulation sont &lt; 1dB pour toutes les inclusions sauf celle de 6mm pour laquelle l\u2019\u00e9cart mesure\/simulation atteint un peu plus de 2dB (comme avec SOV_COMPLET cet \u00e9cart peut \u00eatre attribu\u00e9 \u00e0 une limite du mod\u00e8le concernant le calcul des coefficients de diffraction pour les grands \u00ab\u00a0ka\u00a0\u00bb).<\/li>\n<\/ul>\n<ul class=\"liste-carres-noirs\" style=\"margin-left: 40px;\">\n<li>Autour de \u00ab\u00a0d<sub>max\u00a0<\/sub>\u00bb les formes des courbes amplitude\/distance pr\u00e9dites par le mod\u00e8le SOV ne sont pas en bon accord avec la mesure. Les \u00e9carts mesure\/simulation atteignent plus de 8dB aux distances inf\u00e9rieures \u00e0 la distance focale. A la focale, les amplitudes maximales pr\u00e9dites par le mod\u00e8le SOV sont sous-estim\u00e9es de 2dB environ pour l&rsquo;inclusion de 1mm et surestim\u00e9e\u00a0de 3dB environ pour l&rsquo;inclusion de 6mm. Pour les inclusions de 2 et 4mm, les amplitudes maximales simul\u00e9es et exp\u00e9rimentales montrent\u00a0un bon accord.<\/li>\n<li>la distance \u00ab\u00a0d<sub>max\u00a0<\/sub>\u00bb \u00e0 laquelle l\u2019amplitude de l\u2019\u00e9cho est maximale diminue un peu avec l\u2019augmentation du diam\u00e8tre de l\u2019inclusion :\u00a0d<sub>max<\/sub> varie de 13mm \u00e0 15mm (Tableau 3) ce qui n\u2019est pas en accord avec la mesure. Mais les \u00e9carts entre les valeurs mesur\u00e9e et simul\u00e9e avec SOV sont inf\u00e9rieurs \u00e0 1mm (Tableau 4).<\/li>\n<\/ul>\n<p>Ces comparaisons mesure\/simulations des courbes amplitude\/distance mettent en \u00e9vidence\u00a0:<\/p>\n<\/p>\n<ul class=\"liste-carres-noirs\" style=\"margin-left: 40px;\">\n<li>la n\u00e9cessit\u00e9 d\u2019utiliser les mod\u00e8les SOV_COMPLET et SPECULAIRE plut\u00f4t que le mod\u00e8le SOV pour simuler les \u00e9chos des inclusions quand elles ne sont pas en champ lointain.<\/li>\n<li>le fait qu\u2019en champ lointain du capteur, les mod\u00e8les SOV et SOV_COMPLET donnent des r\u00e9sultats proches.<\/li>\n<li>que les pr\u00e9dictions du mod\u00e8le SPECULAIRE pour l&rsquo;inclusion de 6mm en champ lointain sont plus proches de la mesure que celles obtenues avec le mod\u00e8le SOV_COMPLET pour lequel les \u00e9carts restent faibles. Cette derni\u00e8re observation valide le bridage n\u2019autorisant que le mod\u00e8le SPECULAIRE pour l\u2019inclusion de 6mm dans CIVA.\u00a0\u00a0<\/li>\n<\/ul>\n<p>Un exemple de\u00a0Ascans exp\u00e9rimental et simul\u00e9 des \u00e9chos des inclusions avec SOV-COMPLET et SPECULAIRE sont repr\u00e9sent\u00e9s sur la figure ci-dessous\u00a0pour deux distances \u00ab\u00a0D\u00a0\u00bb entre le capteur et l\u2019inclusion\u00a0L\u2019\u00e9cho sp\u00e9culaire est tr\u00e8s bien pr\u00e9dit par SOV-COMPLET et SPECULAIRE. Le mod\u00e8le SOV-COMPLET pr\u00e9dit \u00e9galement bien la contribution arrivant apr\u00e8s cet \u00e9cho (sauf pour l\u2019inclusion de 1mm). Le mod\u00e8le SPECULAIRE ne simule pas cette contribution.<\/p>\n<\/p>\n<p style=\"text-align:center;\"><img loading=\"lazy\" decoding=\"async\" width=\"548\" height=\"664\" alt=\"\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_27-1.png\" class=\"alignnone wp-image-4557\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_27-1.png 548w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_27-1-248x300.png 248w\" sizes=\"auto, (max-width: 548px) 100vw, 548px\" \/><\/p>\n<\/p>\n<p class=\"wp-caption-text\">Figure 27 : Comparaison des A-scans mesur\u00e9s et simul\u00e9s avec SOV-COMPLET et SPECULAIRE, cas des inclusions de diam\u00e8tre 1 et 2mm, distance capteur\/inclusion de 14.5 (focale exp\u00e9rimentale) et 60mm. Amplitudes normalis\u00e9es non comparables. Capteur plan \u00d86.35mm, 2.25MHz.<\/p>\n<\/p>\n<ul>\n<li>\n<h3 class=\"titre-paragraphe\">Cartographies dans le plan XY \u00e0 la distance focale<\/h3>\n<\/li>\n<\/ul>\n<p>Les courbes \u00e9chodynamiques XY exp\u00e9rimentales et simul\u00e9es avec SOV, SOV_COMPLET et SPECULAIRE,\u00a0extraites \u00e0 la distance capteur\/inclusion de 14.5mm (focale exp\u00e9rimentale) ainsi que la largeur de la tache focale \u00e0 -6dB sont proches (voir illustration\u00a0ci-dessous). Ces courbes sont normalis\u00e9es en amplitude afin de comparer les largeurs focales. On constate que la largeur focale ne d\u00e9pend quasiment pas du diam\u00e8tre de l&rsquo;inclusion, elle est 2mm \u00e0 +\/-0.2mm, sachant que le pas de d\u00e9placement m\u00e9canique est de 0.1mm pour les acquisitions. Elle est tr\u00e8s l\u00e9g\u00e8rement sous-estim\u00e9e en simulation (0.2 \u00e0 0.3mm).<\/p>\n<\/p>\n<p style=\"text-align:center;\"><img loading=\"lazy\" decoding=\"async\" width=\"386\" height=\"389\" alt=\"\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_31-1.png\" class=\"alignnone wp-image-4558\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_31-1.png 386w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_31-1-298x300.png 298w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_31-1-150x150.png 150w\" sizes=\"auto, (max-width: 386px) 100vw, 386px\" \/><\/p>\n<\/p>\n<p class=\"wp-caption-text\">Figure 28 : Comparaison des courbes XY mesur\u00e9es et simul\u00e9es avec SOV, SOV-COMPLET et SPECULAIRE, cas des inclusions de \u00d84 et 6mm. Amplitudes normalis\u00e9es. Capteur plan \u00d86.35mm, 2.25MHz.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-accordeon\">R\u00e9sultats obtenus pour le plan infini<\/h2>\n<\/p>\n<p>Les comparaisons des courbes amplitude\/distance du plan infini, exp\u00e9rimentales et simul\u00e9es avec les mod\u00e8les SPECULAIRE et KIRCHHOFF, montrent un tr\u00e8s bon accord (Figure 29).\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><img loading=\"lazy\" decoding=\"async\" width=\"627\" height=\"291\" alt=\"\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_32-1.png\" class=\"alignnone wp-image-4559\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_32-1.png 627w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_32-1-300x139.png 300w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_32-1-600x278.png 600w\" sizes=\"auto, (max-width: 627px) 100vw, 627px\" \/><\/p>\n<\/p>\n<p class=\"wp-caption-text\">Figure 29 : Comparaison des courbes amplitude\/distance mesur\u00e9e et simul\u00e9es avec SPECULAIRE (avec et sans prise en compte de l\u2019att\u00e9nuation) et KIRCHHOFF, cas du plan infini. R\u00e9f\u00e9rence pour les amplitudes: \u00e9cho L0\u00b0 d\u2019un TG\u00d82mm \u00e0 44mm de profondeur dans la cale d\u2019\u00e9talonnage, hauteur d\u2019eau 20mm. Capteur plan \u00d86.35mm, 2.25MHz.<\/p>\n<\/p>\n<p>Remarque : La figure ci-dessus montre que la prise en compte de l&rsquo;att\u00e9nuation dans l&rsquo;eau\u00a0(0.0087dB\/mm \u00e0 la fr\u00e9quence de 2MHz) est n\u00e9gligeable pour ce capteur.\u00a0On rappelle que pour le calcul des \u00e9chos des inclusions elle n\u2019a pas \u00e9t\u00e9 prise en compte car la distance maximale capteur\/inclusion utilis\u00e9e pour les mesures des \u00e9chos des inclusions n\u2019est que de 74mm.<\/p>\n<\/p>\n<p>Les A-scans exp\u00e9rimental et simul\u00e9 par le mod\u00e8le SPECULAIRE du plan infini sont en tr\u00e8s bon accord Figure 30.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><img loading=\"lazy\" decoding=\"async\" width=\"627\" height=\"330\" alt=\"\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_33-1.png\" class=\"alignnone wp-image-4560\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_33-1.png 627w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_33-1-300x158.png 300w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_33-1-600x316.png 600w\" sizes=\"auto, (max-width: 627px) 100vw, 627px\" \/><\/p>\n<\/p>\n<p class=\"wp-caption-text\">Figure 30 : Comparaison des A-scans mesur\u00e9s et simul\u00e9s avec SPECULAIRE, cas du plan infini. Amplitudes normalis\u00e9es. Capteur plan \u00d86.35mm, 2.25MHz.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-accordeon\">Spectre des \u00e9chos des inclusions et du plan infini<\/h2>\n<\/p>\n<p>Ici, nous comparons les caract\u00e9ristiques (fr\u00e9quence centrale (fc) et bande passante \u00e0 -6dB (BW)) des spectres mesur\u00e9s et simul\u00e9s avec le mod\u00e8le SPECULAIRE du plan infini plac\u00e9 \u00e0 la focale et \u00e0 60mm (champ lointain)\u00a0afin de v\u00e9rifier que CIVA les pr\u00e9dit correctement. Les r\u00e9sultats sont regroup\u00e9s sur le Tableau 5.<\/p>\n<\/p>\n<table align=\"center\" border=\"1\" cellpadding=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td colspan=\"5\" style=\"width:520px;height:33px;\">\n<p style=\"text-align:center;\"><strong>Plan Infini<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width:135px;height:48px;\">\n<p style=\"text-align:center;\"><strong>Distance capteur \/ plan infini<\/strong><\/p>\n<\/td>\n<td colspan=\"2\" style=\"width: 186px; height: 48px;\">\n<p style=\"text-align:center;\"><strong>14.5mm<\/strong><\/p>\n<\/td>\n<td colspan=\"2\" style=\"width: 208px; height: 48px;\">\n<p style=\"text-align:center;\"><strong>60mm<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width:135px;height:33px;\">\n<p style=\"text-align:center;\">\u00a0<\/p>\n<\/td>\n<td style=\"width:84px;height:33px;\">\n<p style=\"text-align:center;\">fc (MHz)<\/p>\n<\/td>\n<td style=\"width: 98px; height: 33px;\">\n<p style=\"text-align:center;\">\u00a0BW (MHz)<\/p>\n<\/td>\n<td style=\"width: 110px; height: 33px;\">\n<p style=\"text-align:center;\">fc (MHz)<\/p>\n<\/td>\n<td style=\"width:94px;height:33px;\">\n<p style=\"text-align:center;\">\u00a0BW (MHz)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width:135px;height:31px;\">\n<p style=\"text-align:center;\"><strong>Mesure<\/strong><\/p>\n<\/td>\n<td style=\"width:84px;height:31px;\">\n<p style=\"text-align:center;\">2<\/p>\n<\/td>\n<td style=\"width: 98px; height: 31px;\">\n<p style=\"text-align:center;\">1.2<\/p>\n<\/td>\n<td style=\"width: 110px; height: 31px;\">\n<p style=\"text-align:center;\">2.2<\/p>\n<\/td>\n<td style=\"width:94px;height:31px;\">\n<p style=\"text-align:center;\">1.25<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width:135px;height:33px;\">\n<p style=\"text-align:center;\"><strong>SPECULAIRE<\/strong><\/p>\n<\/td>\n<td style=\"width:84px;height:33px;\">\n<p style=\"text-align:center;\">2<\/p>\n<\/td>\n<td style=\"width: 98px; height: 33px;\">\n<p style=\"text-align:center;\">1.25<\/p>\n<\/td>\n<td style=\"width: 110px; height: 33px;\">\n<p style=\"text-align:center;\">2.15<\/p>\n<\/td>\n<td style=\"width:94px;height:33px;\">\n<p style=\"text-align:center;\">1.25<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div style=\"clear:both;\">\u00a0<\/div>\n<\/p>\n<p class=\"wp-caption-text\">Tableau 5 : Comparaison des caract\u00e9ristiques issues de r\u00e9sultats de mesure et de simulation avec SOV, SOV_COMPLET et SPECULAIRE (fr\u00e9quence centrale (fc) et bande passante \u00e0 -6dB (BW)) du spectre des \u00e9chos sp\u00e9culaires du plan infini dans l\u2019eau aux distances de 14.5 et 60mm du capteur. Les valeurs en caract\u00e8res gras correspondent aux cas non brid\u00e9s dans CIVA. Capteur plan \u00d86.35mm, 2.25MHz.<\/p>\n<\/p>\n<p>Les m\u00eames caract\u00e9ristiques exp\u00e9rimentales et simul\u00e9es extraites des spectres des \u00e9chos d\u2019inclusions ont \u00e9t\u00e9 compar\u00e9es aux caract\u00e9ristiques issues du plan infini. Le Tableau 6 montre \u00e0 titre d&rsquo;example\u00a0les r\u00e9sultats pour l\u2019inclusion de \u00d81mm.<\/p>\n<\/p>\n<table align=\"center\" border=\"1\" cellpadding=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td colspan=\"5\" style=\"width:552px;height:29px;\">\n<p style=\"text-align:center;\"><strong>Inclusion <\/strong><strong>\u00d8<\/strong><strong>1mm<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width:175px;height:29px;\">\n<p style=\"text-align:center;\"><strong>Distance capteur\/inclusion <\/strong><\/p>\n<\/td>\n<td colspan=\"2\" style=\"width:191px;height:29px;\">\n<p style=\"text-align:center;\"><strong>14.5mm<\/strong><\/p>\n<\/td>\n<td colspan=\"2\" style=\"width:186px;height:29px;\">\n<p style=\"text-align:center;\"><strong>60mm<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width:175px;height:29px;\">\n<p style=\"text-align:center;\">\u00a0<\/p>\n<\/td>\n<td style=\"width:82px;height:29px;\">\n<p style=\"text-align:center;\">fc (MHz<\/p>\n<\/td>\n<td style=\"width:110px;height:29px;\">\n<p style=\"text-align:center;\">\u00a0BW (MHz)<\/p>\n<\/td>\n<td style=\"width:94px;height:29px;\">\n<p style=\"text-align:center;\">fc (MHz)<\/p>\n<\/td>\n<td style=\"width:93px;height:29px;\">\n<p style=\"text-align:center;\">\u00a0BW (MHz)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width:175px;height:29px;\">\n<p style=\"text-align:center;\"><strong>Mesure<\/strong><\/p>\n<\/td>\n<td style=\"width:82px;height:29px;\">\n<p style=\"text-align:center;\"><strong>2<\/strong><\/p>\n<\/td>\n<td style=\"width:110px;height:29px;\">\n<p style=\"text-align:center;\">1.2<\/p>\n<\/td>\n<td style=\"width:94px;height:29px;\">\n<p style=\"text-align:center;\"><strong>2.1<\/strong><\/p>\n<\/td>\n<td style=\"width:93px;height:29px;\">\n<p style=\"text-align:center;\">1.2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width:175px;height:29px;\">\n<p style=\"text-align:center;\"><strong>SOV<\/strong><\/p>\n<\/td>\n<td style=\"width:82px;height:29px;\">\n<p style=\"text-align:center;\"><strong>2<\/strong><\/p>\n<\/td>\n<td style=\"width:110px;height:29px;\">\n<p style=\"text-align:center;\"><strong>\u00a0 1.1<\/strong><\/p>\n<\/td>\n<td style=\"width:94px;height:29px;\">\n<p style=\"text-align:center;\"><strong>2.1 <\/strong><\/p>\n<\/td>\n<td style=\"width:93px;height:29px;\">\n<p style=\"text-align:center;\"><strong>1.1<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width:175px;height:29px;\">\n<p style=\"text-align:center;\"><strong>SOV-COMPLET<\/strong><\/p>\n<\/td>\n<td style=\"width:82px;height:29px;\">\n<p style=\"text-align:center;\"><strong>1.9<\/strong><\/p>\n<\/td>\n<td style=\"width:110px;height:29px;\">\n<p style=\"text-align:center;\"><strong>1<\/strong><\/p>\n<\/td>\n<td style=\"width:94px;height:29px;\">\n<p style=\"text-align:center;\"><strong>2.1<\/strong><\/p>\n<\/td>\n<td style=\"width:93px;height:29px;\">\n<p style=\"text-align:center;\"><strong>\u00a01.05<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width:175px;height:29px;\">\n<p style=\"text-align:center;\"><strong>SPECULAIRE<\/strong><\/p>\n<\/td>\n<td style=\"width:82px;height:29px;\">\n<p style=\"text-align:center;\"><strong>1.9<\/strong><\/p>\n<\/td>\n<td style=\"width:110px;height:29px;\">\n<p style=\"text-align:center;\"><strong>1.1<\/strong><\/p>\n<\/td>\n<td style=\"width:94px;height:29px;\">\n<p style=\"text-align:center;\"><strong>2.1<\/strong><\/p>\n<\/td>\n<td style=\"width:93px;height:29px;\">\n<p style=\"text-align:center;\"><strong>1.3<\/strong><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div style=\"clear:both;\">\u00a0<\/div>\n<\/p>\n<p class=\"wp-caption-text\">Tableau 6 : Comparaison des caract\u00e9ristiques issues de r\u00e9sultats de mesure et de simulation avec SOV, SOV_COMPLET et SPECULAIRE (fr\u00e9quence centrale (fc) et bande passante \u00e0 -6dB (BW)) du spectre des \u00e9chos sp\u00e9culaires de l\u2019inclusion en acier \u00d81mm dans l\u2019eau aux distances de 14.5 et 200mm du capteur. Les valeurs en caract\u00e8res gras correspondent aux cas non brid\u00e9s dans CIVA. Capteur plan \u00d86.35mm, 2.25MHz.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Ces r\u00e9sultats montrent que CIVA pr\u00e9dit bien les fr\u00e9quences centrales et bandes passantes des \u00e9chos du plan infini et des deux inclusions. Les valeurs ne d\u00e9pendent quasiment pas du r\u00e9flecteur.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-accordeon\">Effet d&rsquo;une faible variation de la fr\u00e9quence centrale<\/h2>\n<\/p>\n<p>Nous avons \u00e9valu\u00e9 l\u2019effet d\u2019une variation (arbitraire) de +\/-0.1MHz de la fr\u00e9quence centrale \u00ab\u00a0fc\u00a0\u00bb du signal d\u2019entr\u00e9e (environ 5% de la fr\u00e9quence centrale nominale du capteur) sur les pr\u00e9dictions de CIVA pour les inclusions et le plan infini.\u00a0<\/p>\n<\/p>\n<p>Avant d\u2019\u00e9tudier cet effet sur les \u00e9chos des inclusions et du plan infini, le bon accord exp\u00e9rience\/simulation pour l\u2019\u00e9cho de r\u00e9f\u00e9rence du TG pour les 3 fr\u00e9quences \u00e9valu\u00e9es (2.2MHz, 2.3MHz et 2.4MHz) a \u00e9t\u00e9 v\u00e9rifi\u00e9\u00a0car il est indispensable pour permettre les comparaisons mesure\/simulation pour d\u2019autres r\u00e9flecteurs.<\/p>\n<\/p>\n<p>Les A-scans de l\u2019\u00e9cho de la r\u00e9f\u00e9rence (TG) simul\u00e9s aux 3 fr\u00e9quences sont en accord avec la mesure (Figure 31).\u00a0<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><img loading=\"lazy\" decoding=\"async\" width=\"498\" height=\"181\" alt=\"\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_34.png\" class=\"alignnone wp-image-4561\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_34.png 498w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_34-300x109.png 300w\" sizes=\"auto, (max-width: 498px) 100vw, 498px\" \/><\/p>\n<\/p>\n<p class=\"wp-caption-text\">Figure 31 : Superposition des A-scans mesur\u00e9 et simul\u00e9s avec SOV_COMPLET de l\u2019\u00e9cho du TG de r\u00e9f\u00e9rence. Ces comparaisons montrent que les A-scans simul\u00e9s avec SOV_COMPLET pour des fr\u00e9quences centrales du signal d\u2019entr\u00e9e de 2.2, 2.3 et 2.4MHz sont tous en bon accord avec la mesure. Amplitudes normalis\u00e9es. Capteur plan \u00d86.35mm, 2.25MHz.<\/p>\n<\/p>\n<p>Pareillement, l\u2019amplitude du TG de r\u00e9f\u00e9rence (\u00e0 44mm de profondeur) varie peu avec la fr\u00e9quence centrale: 0.5dB environ (Figure 32).<\/p>\n<\/p>\n<p style=\"text-align:center;\"><img loading=\"lazy\" decoding=\"async\" width=\"374\" height=\"250\" alt=\"\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_35.png\" class=\"alignnone wp-image-4562\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_35.png 374w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_35-300x201.png 300w\" sizes=\"auto, (max-width: 374px) 100vw, 374px\" \/><\/p>\n<\/p>\n<p class=\"wp-caption-text\">Figure 32 : R\u00e9sultats de simulation SOV-COMPLET, \u00e9chos L0\u00b0 de TGs \u00e0 diff\u00e9rentes profondeurs (de 4mm \u00e0 60mm par pas de 4 mm) dans la cale d\u2019\u00e9talonnage. Etude de l\u2019effet d\u2019une faible variation de la fr\u00e9quence centrale du signal d\u2019entr\u00e9e CIVA du capteur sur cette courbe calcul\u00e9e pour 3 fr\u00e9quences: 2.2MHz, 2.3MHz et 2.4MHz. Capteur plan \u00d86.35mm, 2.25MHz, hauteur d\u2019eau de 20mm.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Les courbes amplitude\/distance des inclusions ont \u00e9t\u00e9 simul\u00e9es aux 3 fr\u00e9quences centrales \u00ab\u00a0fc\u00a0\u00bb avec les mod\u00e8les SOV_COMPLET pour les inclusions de \u00d81, 2 et 4mm\u00a0 (Figure 33) et SPECULAIRE pour l\u2019inclusion de \u00d86mm (Figure 34).<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><img loading=\"lazy\" decoding=\"async\" width=\"669\" height=\"331\" alt=\"\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_37.png\" class=\"alignnone wp-image-4563\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_37.png 669w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_37-300x148.png 300w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_37-600x297.png 600w\" sizes=\"auto, (max-width: 669px) 100vw, 669px\" \/><\/p>\n<\/p>\n<p class=\"wp-caption-text\">Figure 33 : R\u00e9sultats de simulation SOV-COMPLET, courbes amplitude\/distance des inclusions en acier dans l\u2019eau. Etude de l\u2019effet d\u2019une faible variation de la fr\u00e9quence centrale sur ces courbes obtenues pour 3 fr\u00e9quences: 2.2MHz, 2.3MHz et 2.4MHz. Capteur plan \u00d86.35mm, 2.25MHz.<\/p>\n<p>\u00a0<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p style=\"text-align:center;\"><img loading=\"lazy\" decoding=\"async\" width=\"436\" height=\"223\" alt=\"\" src=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_38.png\" class=\"alignnone wp-image-4564\" srcset=\"https:\/\/www.extende.com\/wp-content\/uploads\/Figure_38.png 436w, https:\/\/www.extende.com\/wp-content\/uploads\/Figure_38-300x153.png 300w\" sizes=\"auto, (max-width: 436px) 100vw, 436px\" \/><\/p>\n<\/p>\n<p class=\"wp-caption-text\">Figure 34 : R\u00e9sultats de simulation SPECULAIRE, courbe amplitude\/distance de l\u2019inclusion en acier de \u00d86mm dans l\u2019eau. Etude de l\u2019effet d\u2019une faible variation de la fr\u00e9quence centrale sur cette courbe calcul\u00e9e pour 3 fr\u00e9quences: 2.2MHz, 2.3MHz et 2.4MHz. Capteur plan \u00d86.35mm, 2.25MHz.<\/p>\n<\/p>\n<p>Ces r\u00e9sultats\u00a0montrent qu\u2019une variation de fr\u00e9quence centrale\u00a0modifie l\u2019amplitude maximale des courbes amplitude\/distance\u00a0de 2 \u00e0 2.5dB. Cependant,\u00a0quand les inclusions s\u2019\u00e9loignent du capteur, les amplitudes de leurs \u00e9chos varient peu avec fc.<\/p>\n<\/p>\n<p>Ainsi, si on modifie de 0.1MHz la fr\u00e9quence centrale du signal d\u2019entr\u00e9e de CIVA, les amplitudes maximales des courbes amplitude\/distance des inclusions peuvent varier de 2 dB\u00a0environ si on choisit comme r\u00e9f\u00e9rence pour les amplitudes le TG \u00e0 44mm de profondeur. De plus, la position du maximum des courbes amplitude\/distance varie de 1.5mm. Ces variations peuvent \u00eatre consid\u00e9r\u00e9es comme des incertitudes sur les r\u00e9sultats de simulation CIVA li\u00e9es \u00e0 l\u2019incertitude sur la valeur de la fr\u00e9quence centrale du signal d\u2019entr\u00e9e.\u00a0<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<h2 class=\"titre-accordeon\">Synth\u00e8se<\/h2>\n<\/p>\n<p>Un tr\u00e8s bon accord a \u00e9t\u00e9 obtenu pour ce capteur entre la mesure et les simulations SOV_COMPLET et SPECULAIRE pour :<\/p>\n<\/p>\n<ul>\n<li>les courbes amplitude\/distance des inclusions et du plan infini,<\/li>\n<li>les courbes \u00ab\u00a0XY\u00a0\u00bb des inclusions,<\/li>\n<li>les Ascans des \u00e9chos et leurs spectres.<\/li>\n<\/ul>\n<p>La surestimation des amplitudes des \u00e9chos de l\u2019inclusion de \u00d86mm en champ lointain avec SOV et SOV_COMPLET justifie le bridage pr\u00e9sent\u00a0actuellement dans CIVA et qui n\u2019autorise\u00a0le calcul des \u00e9chos de cette inclusion qu\u2019avec le mod\u00e8le SPECULAIRE. L\u2019apport de SOV_COMPLET par rapport \u00e0 SOV a \u00e9t\u00e9 mis en \u00e9vidence pour les \u00e9chos des inclusions quand elles sont pr\u00e8s du capteur.<\/p>\n<\/p>\n<p>\u00a0<\/p>\n<\/p>\n<p>Continuer vers <a class=\"g-lien\" href=\"https:\/\/www.extende.com\/fr\/la-simulation-cnd\/documentation\/validation-experimentale-des-modeles-civa\/validation-experimentale-des-modeles-civa-en-ultrasons\/caracterisation-du-champ-de-capteurs-dans-leau-par-mesure-des-echos-dinclusion-solides-et-dun-plan-infini\/capteurs-mono-element\/inclusion-dans-leau-monoelement-capteur-5-mhz\/\">R\u00e9sultats obtenus avec le capteur 5 MHz<\/a><\/p>\n<\/p>\n<p>Retour vers <a class=\"g-lien\" href=\"https:\/\/www.extende.com\/fr\/la-simulation-cnd\/documentation\/validation-experimentale-des-modeles-civa\/validation-experimentale-des-modeles-civa-en-ultrasons\/caracterisation-du-champ-de-capteurs-dans-leau-par-mesure-des-echos-dinclusion-solides-et-dun-plan-infini\/capteurs-mono-element\/inclusion-dans-leau-monoelement-description-des-simulations\/\">Description des simulations<\/a><\/p>\n<\/p>\n<p>Retour vers <a class=\"g-lien\" href=\"https:\/\/www.extende.com\/fr\/la-simulation-cnd\/documentation\/validation-experimentale-des-modeles-civa\/validation-experimentale-des-modeles-civa-en-ultrasons\/caracterisation-du-champ-de-capteurs-dans-leau-par-mesure-des-echos-dinclusion-solides-et-dun-plan-infini\/capteurs-mono-element\/\" target=\"_self\">Capteurs mono-\u00e9l\u00e9ment<\/a><\/p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Param\u00e8tres d&rsquo;entr\u00e9e dans CIVA \u00a0 Param\u00e8tres du capteur Le diam\u00e8tre du capteur entr\u00e9 dans CIVA est celui donn\u00e9 par le fabricant\u00a0: Diam\u00e8tre du capteur\u00a0: 6.35mm La fr\u00e9quence centrale du signal d\u2019entr\u00e9e est la fr\u00e9quence nominale donn\u00e9e par le fabricant : Fr\u00e9quence centrale = 2.25 MHz Les deux autres param\u00e8tres du signal d\u2019entr\u00e9e, la bande passante [&hellip;]<\/p>\n","protected":false},"author":0,"featured_media":0,"parent":3446,"menu_order":2,"comment_status":"closed","ping_status":"closed","template":"templates\/page--extende.html.php","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-4566","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.extende.com\/fr\/wp-json\/wp\/v2\/pages\/4566","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.extende.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.extende.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"replies":[{"embeddable":true,"href":"https:\/\/www.extende.com\/fr\/wp-json\/wp\/v2\/comments?post=4566"}],"version-history":[{"count":1,"href":"https:\/\/www.extende.com\/fr\/wp-json\/wp\/v2\/pages\/4566\/revisions"}],"predecessor-version":[{"id":5523,"href":"https:\/\/www.extende.com\/fr\/wp-json\/wp\/v2\/pages\/4566\/revisions\/5523"}],"up":[{"embeddable":true,"href":"https:\/\/www.extende.com\/fr\/wp-json\/wp\/v2\/pages\/3446"}],"wp:attachment":[{"href":"https:\/\/www.extende.com\/fr\/wp-json\/wp\/v2\/media?parent=4566"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}